PLC-HP7000L Expand Serial Command Functional Specifications
34/94
8.7.3 CF_VSCALE Command
Command “CF_VSCALE_%1” [CR]
%1
“035” ---------------------- +35
“031” ---------------------- +31
:
“002” ---------------------- +2
“001” ---------------------- +1
“000” ---------------------- ±0
“
‐
01” ---------------------
‐
1
“
‐
02” ---------------------
‐
2
:
“
‐
31” ---------------------
‐
31
“
‐
32” ---------------------
‐
32
“UP” --------------------- Increment setting value of Vscale by 1
“DN” --------------------- Decrement setting value of Vscale by 1
Details
Set Vscale (Available only in the normal Power ON status)
*When the screen mode is not in “Custom”, projector changes image mode into
Custom by receiving this command.
*When there is no signal detected, projector returns 101 and the command does
not execute.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.7.4 CF_VPOS Command
Command “CF_VPOS_%1” [CR]
%1
“015” --------------------- +15
“014” --------------------- +14
:
“002” --------------------- +2
“001” --------------------- +1
“000” --------------------- ±0
“
‐
01” ---------------------
‐
1
“
‐
02” ---------------------
‐
2
:
“
‐
14” ---------------------
‐
14
“
‐
15” ---------------------
‐
15
“UP” --------------------- Increment setting value of Vposition by 1
“DN” --------------------- Decrement setting value of Vposition by 1
Details
Set V Position (Available only in the normal Power ON status)
*When the screen mode is not in “Custom”, projector changes image mode into
Custom by receiving this command.
*When there is no signal detected, projector returns 101 and the command does
not execute.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]