PLC-HP7000L Expand Serial Command Functional Specifications
51/94
%1
“0400” ---------------------- Set 400 hours
“0700” ---------------------- Set 700 hours
“1000” ---------------------- Set 1000 hours
“OFF” ---------------------- Set Off(Do not warning display)
Details
Set time to display Filter cleaning / replacement warning on screen
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.43 CF_FILCTL Command
Command “CF_FILCTL_%1” [CR]
%1
“ROLL” ---------------------- Execute operation of scroll of filter
Details
Execute operation of scroll of filter
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.44 CF_FILSCRL Command
Command “CF_FILSCRL_%1” [CR]
%1
“RST” ---------------------- Reset Filter scroll counter
Details
Reset Filter scroll counter
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.45 CF_FANSPEED Command
Command “CF_FANSPEED_%1” [CR]
%1
“MAX” ------------------------------ Select maximum fan speed
“NOR” ------------------------------ Select normal fan speed
Details
Switch Fan Control Speed mode.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.46 CF_SIMPLEMODE Command
Command “CF_SIMPLEMODE_%1” [CR]
%1
“ON” ------------------------------ Set Simple mode to ON
“OFF” ------------------------------ Set Simple mode to OFF
Details
Set Simple mode.(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.9.47 CF_RCODE Command
Command “CF_RCODE_%1” [CR]
%1
“001” ------------------------------------ Select Code 1
“002” ------------------------------------ Select Code 2
“003” ------------------------------------ Select Code 3