PLC-HP7000L Expand Serial Command Functional Specifications
67/94
9.5.10 CR_SETPCADJ Command
Command “CR_SETPCADJ” [CR]
Details
Get PC signal for current system
Acceptable
“000_%1” [CR]
%1
When input signal is PC Analog;
“VGA1” ------------------------ Indicates VGA1 is selected
“VGA2” ------------------------ Indicates VGA2 is selected
:
“XGA1” ------------------------ Indicates XGA1 is selected
:
“WXGA3” --------------------- Indicates WXGA3 is selected
“1080P” ------------------------ Indicates 1080p is selected
“1080I” ------------------------ Indicates 1080i is selected
“1035I” ------------------------ Indicates 10350i is selected
“720P” ------------------------- Indicates 720p is selected
“575P” ------------------------- Indicates 575p is selected
“480P” ------------------------- Indicates 480p is selected
“575I” -------------------------- Indicates 575i is selected
“480I” -------------------------- Indicates 480i is selected
“1080PSF/24” ----------------- Indicates 1080psf/24 is selected
“1080PSF/25” ----------------- Indicates 1080psf/25 is selected
“1080PSF/30” ----------------- Indicates 1080psf/30 is selected
:
“MODE10” ------------------- Indicates Mode10 is selected
“EXT11” ---------------------- EXT11 is selected
:
“EXT60” ---------------------- EXT60 is selected
* Error Code “101” [CR] is returned for no signal.
* When input signal is not PC Analog, error code “101” is
returned.
Response
Unacceptable “Error Code” [CR]