PLC-HP7000L Expand Serial Command Functional Specifications
21/94
8.4.5 CF_COLMNSAV Command
Command “CF_COLMNSAV_%1” [CR]
%1
“000 – 009” ---------------- Specify the area to store
Details
Store current setting status of Color Management to the area specified in %1.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.6 CF_COLMNLD Command
Command “CF_COLMNLD_%1” [CR]
%1
“000 – 009” ---------------- Specify the area to store
Details
Retrieve Color Management setting status from the area specified in %1.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“Error Code” [CR]
8.4.7 CF_SHARP Command
Command
“CF_SHARP_%1” [CR]
%1
“000-031”--------------- Directly specify setting value of Sharpness
“UP”--------------------- Increment setting value of Sharpness by 1
“DN”--------------------- Decrement setting value of Sharpness by 1
Details
Set user controlled value of Sharpness (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.8 CF_GAMMA Command
Command “CF_GAMMA_%1” [CR]
%1
“000-015”---------------- Directly specify setting value of Gamma
“UP”---------------------- Increment setting value of Gamma by 1
“DN”---------------------- Decrement setting value of Gamma by 1
Details
Set user controlled value of Gamma (Available only in the normal Power ON
status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable “Error Code” [CR]