PLC-HF15000L Expand Serial Command Functional Specifications
29/105
8.5.4 CF_V-POS Command
Command
“CF_V-POS_%1” [CR]
%1
“0000-nnnn” ------------ Directly specify setting value of Vertical Position
“nnnn” indicates maximum value, which is current (Total Line – Display Area V) value
“UP” --------------------- Increment setting value of Vertical Position by 1
“DN” --------------------- Decrement setting value of Vertical Position by 1
Details
Set Vertical Position value in PC signal (Available only in the normal Power ON
status)
The value set by this command is not stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal
8.5.5 CF_CLAMP Command
Command
“CF_CLAMP_%1” [CR]
%1
“0000-4095” ----------- Directly specify setting value of Clamp
“UP” --------------------- Increment setting value of Clamp by 1
“DN” --------------------- Decrement setting value of Clamp by 1
Details
Set Clamp value in PC signal. (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector’s memory.
Therefore, when the power is turned to ALL OFF stasis, the value returns to the
original setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal
8.5.6 CF_DDOTS Command
Command
“CF_DDOTS_%1” [CR]
%1
“0256-nnnn” ----------------- Directly specify setting value of Display Dots
“nnnn” indicates maximum value, which is current value of (Total Dots - Position H).
In this projector, the value should be “even number” and if “odd number” is specified,
it adds 1 to make the value even number.
“UP” ------------------- Increment setting value of Display Dots by 2
“DN” ------------------- Decrement setting value of Display Dots by 2
Details
Set Display Dots value in PC signal. (Available only in the normal Power ON
status)
The value set by this command is not stored in the projector’s memory. Therefore,
when the power is turned to ALL OFF status, the value returns to the original
setting. (It is stored in Suspend mode.)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal