background image

Printed in China
9NK5012072400
11P05-CH-NM

INSTALLATION MANUAL

CAUTION:
• Potential hazard of glass particles if lamp ruptures. Please have a Sharp Authorized Projector Dealer or 

Service Center* replace lamp if rupture occurs.

• Do not remove the lamp unit directly after operation of the projector. The lamp may be extremely hot. Wait 

at least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool 
before removing the lamp unit.

It is recommended that the lamp be replaced when the remaining lamp life becomes 5% or less, or when you notice a signifi -
cant deterioration in the picture and color quality. The lamp life (percentage) can be checked with the on-screen display.

IMPORTANT NOTE TO U.S. CUSTOMERS:

The lamp included with this projector is backed by a 90-day parts and labor limited warranty. All service of 
this projector under warranty, including lamp replacement, must be obtained through a Sharp Authorized 
Projector Dealer or Service Center*. For the name of the nearest Sharp Authorized Projector Dealer or 
Service Center*, please call toll-free: 1-888-GO-SHARP (1-888-467-4277).

Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
www.lamprecycle.org or 1-800-BE-SHARP 

U.S.A. ONLY

* Confi rm the name of the Dealer or Service Center referring to your projector operation manual.

LAMP UNIT (LAMP/CAGE MODULE) 
FOR PROJECTOR

MODEL

 AN-PH80LP

Removing and Installing the 
Lamp Unit

Warning!

Do not remove the lamp unit from the projector right 
after use. The lamp and parts around the lamp will 
be very hot and may cause burns or injury.

Info

Do not touch the glass surface of the lamp unit or 
the inside of the projector. 
To avoid injury to yourself and damage to the lamp, 
make sure you carefully follow the steps below.
Do not loosen other screws except for the lamp unit 
cover and lamp unit.

1

 Press 

STANDBY/ON

 on the projector 

or on the remote control to put the 
projector into Standby mode.

2

  Switch the MAIN POWER switch on 

the projector to “OFF” and then 
disconnect the power cord.

Unplug the power cord from the AC socket.
Leave the lamp until it has fully cooled down 
(about 1 hour).

3

  Remove the lamp unit cover.

Loosen the user service screw (

1

) that secures the 

lamp unit cover. Remove the lamp unit cover (

2

).


1

2

3

4

  Remove the lamp unit.  

Loosen the securing screws (two for each lamp) 
from the lamp unit. Hold the lamp unit by the 
handle and pull it in the direction of the arrow. At 
this time, keep the lamp unit horizontal and do not 
tilt it.

5

  Insert the new lamp unit.

Press the lamp unit fi rmly into the lamp unit 
compartment. Fasten the securing screw.

6

  Replace the lamp unit cover.

Align the lamp unit cover and slide it to close (

1

). 

Then tighten the user service screw (

2

) to secure 

the lamp unit cover.

Info

If the lamp unit and lamp unit cover are not 
correctly installed, the power will not turn on, 
even if the power cord is connected to the 
projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp. 

Info

Make sure to reset the lamp timer only when 

replacing the lamp. If you reset the lamp timer and 

continue to use the same lamp, this may cause the 

lamp to become damaged or explode.

You can reset the lamp timer only when “STANDBY 

mode” is set to “Standard”.

1

  Connect the power cord and switch 

the MAIN POWER switch on the 
projector to “ON”.

Plug the power cord into the AC socket of the 
projector.

2

  Reset the lamp timer.

The projector enters Standby mode when you 
reset the lamp timer. 

For Lamp 1

When you reset the timer, press 

MENU

ENTER

ENTER

MENU

O

STANDBY/ON

 on 

the projector.
“LAMP1 0000H” is displayed, indicating that the 
lamp timer is reset.

For Lamp 2

When you reset the timer, press 

MENU

ENTER

ENTER

MENU

Q

STANDBY/ON

 on 

the projector.
“LAMP2 0000H” is displayed, indicating that the 
lamp timer is reset.

4

5

6

1

2

STANDBY/ON button

AC socket

MAIN POWER switch

User service screw 
(for lamp unit cover)

AC socket

ENTER button

MENU button

O

/

Q

 buttons

STANDBY/ON 
button

AN-PH80LP̲OptionLamp.indd   1

AN-PH80LP̲OptionLamp.indd   1

2011/04/20   10:14:54

2011/04/20   10:14:54