-7-
Circuit Protections
Warning temperature and power failure protection
The TEMP WARNING indicator flashes red and the projector will automatically turn off when the internal tempera-
ture of the projector exceeds the normal temperature or when stopping cooling fans or when the internal power sup-
ply lines are failed.
Check the following possible causes and wait until stopping the TEMP WARNING indicator flashing.
Possible causes
- Air filter is clogged with dust particles. Remove dust from the air filter by following instructions in the “Air filter care
and cleaning” below.
- Ventilation slots of the projector are blocked. In such an event, reposition the projector so that ventilation slots are
not obstructed.
- Check if projector is used at higher temperature place (Normal operating temperature is 5 to 35 ˚C)
If the TEMP WARNING indicator still continues to flash, there may be defects on cooling fans or power supply cir-
cuits. Please check fan operation and power supply lines referring to the “Power Supply Lines Chart”.
Air Filter care and cleaning
The removable air filter prevents dust from accumulation on the surface of
the projection lens and projection mirror. Should be the air filter become
clogged with dust particles, it will reduce the cooling fan’s effectiveness
and may result in internal heat build up and reduce the life of the projector.
To clean up the air filter, follow the cleaning procedure below:
1. Turn the MAINS ON/OFF switch to OFF, and disconnect the AC power
code from the AC outlet.
2. Remove the air filter cover.
Press the cover latch sideway and lift the cover.
3. Remove the air filter and sponge from the filter cover.
4. Clean the air filter with a vacuum cleaner.
5. Replace the air filter and sponge. Make sure that air filter cover is fully
inserted.
CAUTION:
Do not clean with water. Doing so may damage the air filter.
Do not operate the projector with air filter removed.
RECOMMENDATION
We recommend to avoid dusty, smoky place for operating the projector.
Using in dusty place may cause the picture of poor quality.
When using under the dusty or smoky conditions, dust may accumulate on
the LCD panel and lens inside it, and may resultantly be projected on the
screen together with the picture.
When the above symptoms are noticed, please clean up the LCD panel
and lens following to the “Cleaning Method”.
Air filter cover
Air filter cover
Sponge
Air filter
Summary of Contents for PLC-EF12B
Page 55: ... 55 IC Block Diagrams AV9155C OSC IC3301 IC3321 CIP3250A Component Interface Processor IC102 ...
Page 58: ... 58 IC Block Diagrams ML60851ATB USB Controller IC3801 MPC948FA Clock Driver IC3341 ...
Page 59: ... 59 IC Block Diagrams M62358FP DAC IC1401 VPC3215C Digital Video Processor IC101 ...
Page 60: ... 60 IC Block Diagrams MB40988PFQ D A Converter IC1181 MSM54V16258 DRAM IC2301 IC2311 ...
Page 61: ... 61 IC Block Diagrams CXA2016S Sync Separator IC4141 TC4052BF Sync Separator IC4141 ...
Page 66: ... 66 TDA8395T SECAM Decoder IC6103 IC Block Diagrams ...
Page 111: ...M6V EF12N00 NL00 PLC EF12E 00 EL 00 PLC EF12B 00 111 ...
Page 112: ... M6VAC Feb 2001 2000 SI Printed in Japan SANYO Electric Co Ltd ...