3
WARNING:
The chassis of this projector is isolated (COLD) from AC line by using the converter transformer. Primary side of
the converter and lamp power supply unit circuit is connected to the AC line and it is hot, which hot circuit is iden-
tified with the line (
) in the schematic diagram. For continued product safety and protection of personnel
injury, servicing should be made with qualified personnel.
The following precautions must be observed.
■
Safety Instructions
SAFETY PRECAUTIONS
1: An isolation transformer should be connected in the
power line between the projector and the AC line
before any service is performed on the projector.
2: Comply with all caution and safety-related notes pro-
vided on the cabinet back, cabinet bottom, inside the
cabinet or on the chassis.
3: When replacing a chassis in the cabinet, always be
certain that all the protective devices are installed
properly, such as, control knobs, adjustment covers
or shields, barriers, etc.
DO NOT OPERATE THIS PROJECTOR WITHOUT
THE PROTECTIVE SHIELD IN POSITION AND
PROPERLY SECURED.
4: Before replacing the cabinet cover, thoroughly
inspect the inside of the cabinet to see that no stray
parts or tools have been left inside.
Before returning any projector to the customer, the
service personnel must be sure it is completely safe to
operate without danger of electric shock.
SERVICE PERSONNEL WARNING
Eye damage may result from directly viewing the light produced by the Lamp used in this equipment. Always turn
off Lamp before opening cover. The Ultraviolet radiation eye protection required during this servicing.
Never turn the power on without the lamp to avoid electric-shock or damage of the devices since the stabilizer
generates high voltages(15kV - 25kV) at its starts.
Since the lamp is very high temperature during units operation replacement of the lamp should be done at least
45 minutes after the power has been turned off, to allow the lamp cool-off.
PRODUCT SAFETY NOTICE
Product safety should be considered when a component replacement is made in any area of the projector.
Components indicated by mark
in the parts list and the schematic diagram designate components in which
safety can be of special significance. It is, therefore, particularly recommended that the replacement of there parts
must be made by exactly the same parts.
DO NOT ATTEMPT TO SERVICING THE
REMOTE CONTROL UNIT.
Laser Beam may be leaked out when in disassemble
the Unit. As the Laser Beam used in this Remote con-
trol unit is harmful to the eyes.
LASER RADIATION
DO NOT STARE INTO BEAM
MAX. OUTPUT: 1mW
WAVE LENGTH: 660
±
20nm
CLASS
II
LASER PRODUCT
This product is complied with 21 CFR
part 1040.10
CAUTION
LASER RADIATION
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
LASER-STRAHLING
NICHT IN DEN STRAHL BLICKEN
LASER KLASSE 2
IEC60825-1, Am. 1 1997
MAX OUTPUT (
) : 1 mW
WAVE LENGTH (
) : 660
±
20nm
Summary of Contents for PLC-EF12B
Page 55: ... 55 IC Block Diagrams AV9155C OSC IC3301 IC3321 CIP3250A Component Interface Processor IC102 ...
Page 58: ... 58 IC Block Diagrams ML60851ATB USB Controller IC3801 MPC948FA Clock Driver IC3341 ...
Page 59: ... 59 IC Block Diagrams M62358FP DAC IC1401 VPC3215C Digital Video Processor IC101 ...
Page 60: ... 60 IC Block Diagrams MB40988PFQ D A Converter IC1181 MSM54V16258 DRAM IC2301 IC2311 ...
Page 61: ... 61 IC Block Diagrams CXA2016S Sync Separator IC4141 TC4052BF Sync Separator IC4141 ...
Page 66: ... 66 TDA8395T SECAM Decoder IC6103 IC Block Diagrams ...
Page 111: ...M6V EF12N00 NL00 PLC EF12E 00 EL 00 PLC EF12B 00 111 ...
Page 112: ... M6VAC Feb 2001 2000 SI Printed in Japan SANYO Electric Co Ltd ...