PDG-DWL2500 Expand Serial Command Functional Specifications
33/72
8.8 Lamp Command
8.8.1
CF_LAMPH Command
Command “CF_LAMPH_%1”[CR]
%1
“RST”
Details
Reset Lamp use time counter.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.8.2
CF_LAMPMODE Command
Command “CF_LAMPMODE_%1”[CR]
%1
“NORMAL” ------- Set lamp to Normal mode status
“ECO” ------------- Set lamp to 3L mode status
“UP” --------------- The same operation as pressing Up key or Left key
“DN” --------------- The same operation as pressing Down key or Right key
Details
Select Lamp Mode
The value set by this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]