PDG-DWL2500 Expand Serial Command Functional Specifications
66/72
9.11.19 CR_CCAPTIONDISP Command
Command “CR_CCAPTIONDISP”[CR]
Details
Get selected channel of Closed caption
Acceptable
“000_%a”[CR]
%
a
“OFF” --------- Off
“CC1” --------- CC1 is selected
“CC2” --------- CC2 is selected
“CC3” --------- CC3 is selected
“CC4” --------- CC4 is selected
Response
Unacceptable “Error Code”[CR]
9.11.20 CR_CCAPTIONCOLOR Command
Command “CR_CCAPTIONCOLOR”[CR]
Details
Get selected color of Closed caption
Acceptable
“000”[CR]
%a
“COLOR” ------- Color is selected
“WHITE” -------- White is selected
Response
Unacceptable “Error Code”[CR]
9.11.21 CR_RCODE Command
Command “CR_RCODE”[CR]
Details
Get selected Remote Control Code
Acceptable
“000_%a”[CR]
%a
“001” --------------------------- Code1 is selected
“002” --------------------------- Code2 is selected
Response
Unacceptable “Error code”[CR]
9.11.22 CR_SECURITY Command
Command “CR_SECURITY” [CR]
Details
Get Security Mode setting status
Acceptable
“000_%1[CR]
%1
“ON” ------------- PJ Lock setting on Menu is ON-1 or ON-2
“OFF” ------------PJ Lock setting on Menu is OFF
Response
Unacceptable “Error Code” [CR]
9.11.23 CR_KEYDIS Command
Command “CR_KEYDIS”(CR)
Details
This command is available to models with top panel buttons only.
Get disability status of RC/Projector keys (valid or invalid)
Acceptable
“000_%a”[CR]
%a
“NONE” -------------------------- RC / Projector keys are valid
“RC” ------------------------------ RC keys are invalid
“KEY” ----------------------------- Projector keys are invalid
Response