PDG-DWL2500 Expand Serial Command Functional Specifications
25/72
8.6.2
CF_SOURCE Command
Command “CF_SOURCE_%1”[CR]
Input is
Computer 1
“ANALOG” --------- Select Analog Input
“YPBPR” ----------- Select Component Input
“SCART” ----------- Select Scart Input
”UP” ---------------- The same operation as pressing Up key or Left
key
”DN” ---------------- The same operation as pressing Down key or
Right key
Input is
Computer 2
““ANALOG” --------- Select Analog Input
”UP”
”DN”
Projector accepts parameter ”UP”/”DN” but no operation is made.
Input is HDMI
“HDMI” ----------- Select HDMI Input
”UP”
”DN”
Projector accepts parameter ”UP”/”DN” but no operation is made.
Input is Video
“VIDEO” ------------- Select Composite Video Input
”UP”
”DN”
Projector accepts parameter ”UP”/”DN” but no operation is made.
%1
Input is
S-video
S-VIDEO ------------- Select S-video Input
”UP”
”DN”
Projector accepts parameter ”UP”/”DN” but no operation is made.
Details
Select Source of currently selected Input
When Input specified by %1 is inappropriate for selected Input, the projector
returns “101” and the command is not executed.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.6.3
CF_INPUT1 Command
Command “CF_INPUT1_%1_”[CR]
%1
“ANALOG” ---------- Select Analog RGB Input
“YPBPR” ------------- Select Component
“SCART” ------------- Select SCART
Details
Select Input - Computer 1 and source specified in %1 at once.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.6.4
CF_INPUT2 Command
Command “CF_INPUT2_%1_”[CR]
%1
“ANALOG” ---------- Select Analog RGB Input
Details
Select Input - Computer 2 and source specified in %1 at once.
This command is available in normal Power ON status.
Projector returns “101” by selecting Computer 2 while Monitor out is selected in
Terminal menu.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]