1. Specifications
Cooling:
Rating Conditions
: Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature
95
°
F DB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / 67
°
F WB
Outdoor Air Temperature 115
°
F DB
Heating:
Rating Conditions
: Indoor Air Temperature
70
°
F DB / 60
°
F WB
Outdoor Air Temperature
47
°
F DB / 43
°
F WB
Full Load Conditions : Indoor Air Temperature
80
°
F DB / —
°
F WB
Outdoor Air Temperature
45
°
F DB / 35
°
F WB
Indoor model: KH2442 / Outdoor model: CH2442
●
Cooling
●
Heating
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.4 - 0.4
0.9 - 0.9
9.0 - 9.6
10.3 - 10.9
kW
0.08 - 0.07
0.18 - 0.17
2.04 - 1.98
2.30 - 2.22
Full load conditions
A
0.4 - 0.4
0.9 - 0.9
11.0 - 11.7
12.3 - 13.0
kW
0.08 - 0.07
0.18 - 0.17
2.46 - 2.44
2.72 - 2.68
Starting amperes
A
1 - 1
1 - 1
66 - 60
68 - 62
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at
230 - 208 V / 1 phase / 60 Hz
230 - 208 V / 1 phase / 60 Hz
Rating conditions
A
0.4 - 0.4
0.9 - 0.9
10.0 - 10.9
11.3 - 12.2
kW
0.08 - 0.07
0.18 - 0.17
2.24 - 2.19
2.50 - 2.43
Full load conditions
A
0.4 - 0.4
0.9 - 0.9
11.1 - 11.7
12.4 - 13.0
kW
0.08 - 0.07
0.18 - 0.17
2.52 - 2.44
2.78 - 2.68
Starting amperes
A
1 - 1
1 - 1
66 - 60
68 - 62