I - 64
SM830082
1
2
3
4
5
1. Specifications
Indoor Unit: UH2442
Outdoor Unit: CH2442
• 208V / 1 phase / 60Hz
RATING CAPACITY :
23,400 BTU/h
AIR FLOW RATE:
600 CFM
EVAPORATOR
CONDENSER
ENT.TEMP.
°
F(
°
C)
AMBIENT TEMP
°
F(
°
C)
WB
DB
75
85
95
105
115
(23.9)
(29.4)
(35.0)
(40.6)
(46.1)
TC
23,700
22,560
21,250
19,770
18,140
CI
1.75
1.92
2.09
2.33
2.56
72(22.2)
SHC
16,860
16,260
15,590
14,850
14,050
59
76(24.4)
SHC
18,930
18,330
17,660
16,910
16,120
(15.0)
80(26.7)
SHC
21,090
20,490
19,820
19,070
18,140
84(28.9)
SHC
23,150
22,560
21,250
19,770
18,140
88(31.1)
SHC
23,700
22,560
21,250
19,770
18,140
TC
24,590
23,490
22,320
20,990
19,540
CI
1.77
1.94
2.12
2.36
2.6
72(22.2)
SHC
14,280
13,750
13,190
12,580
11,920
63
76(24.4)
SHC
16,340
15,810
15,260
14,640
13,990
(17.2)
80(26.7)
SHC
18,500
17,970
17,420
16,800
16,150
84(28.9)
SHC
20,570
20,040
19,490
18,870
18,210
88(31.1)
SHC
22,630
22,100
21,550
20,940
19,540
TC
25,530
24,520
# 23,400
22,160
20,800
CI
1.79
1.96
2.14
2.39
2.63
72(22.2)
SHC
11,680
11,230
10,750
10,220
9,660
67
76(24.4)
SHC
13,740
13,300
12,810
12,290
11,720
(19.4)
80(26.7)
SHC
15,900
15,460
14,970
14,450
13,880
84(28.9)
SHC
17,970
17,530
17,040
16,510
15,950
88(31.1)
SHC
20,040
19,590
19,110
18,580
18,010
TC
26,890
25,950
24,940
23,840
22,630
CI
1.81
1.98
2.17
2.42
2.67
72(22.2)
SHC
9,110
8,730
8,330
7,900
7,440
71
76(24.4)
SHC
11,170
10,800
10,400
9,970
9,500
(21.7)
80(26.7)
SHC
13,330
12,960
12,560
12,130
11,660
84(28.9)
SHC
15,400
15,020
14,620
14,190
13,730
88(31.1)
SHC
17,460
17,090
16,690
16,260
15,800
TC
27,420
26,540
25,600
24,520
23,380
CI
1.84
2.01
2.2
2.46
2.71
75
76(24.4)
SHC
8,360
8,050
7,710
7,330
6,940
(23.9)
80(26.7)
SHC
10,520
10,210
9,870
9,490
9,100
84(28.9)
SHC
12,590
12,270
11,940
11,560
11,170
88(31.1)
SHC
14,660
14,340
14,000
13,630
13,230
TC :Total Cooling Capacity (BTU/h)
SHC:Sensible Heat Capacity (BTU/h)
CI :Compressor Input (kW)
Rating conditions are
M.R.=
7.69
USpints/h
:Outdoor Ambient Temp.95
°
FDB
:Indoor Unit Entering Air Temp.80
°
FDB/67
°
FWB