Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range
Note
6 DIMMER_CTRL_LEVEL7
Luminance Level 7 Data for Dimmer: Dim
Level 7 at the less than the Value
61
0 - 255
7 DIMMER_CTRL_LEVEL8
Luminance Level 8 Data for Dimmer: Dim
Level 8 at the less than the Value
70
0 - 255
8 DIMMER_CTRL_LEVEL9
Luminance Level 9 Data for Dimmer: Dim
Level 9 at the less than the Value
79
0 - 255
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for Dimmer: Dim
Level 10 at the less than the Value
88
0 - 255
10 DIMMER_CTRL_LEVEL11
Luminance Level 11 Data for Dimmer: Dim
Level 11 at the less than the Value
96
0 - 255
11 DIMMER_CTRL_LEVEL12
Luminance Level 12 Data for Dimmer: Dim
Level 12 at the less than the Value
105
0 - 255
12 DIMMER_CTRL_LEVEL13
Luminance Level 13 Data for Dimmer: Dim
Level 13 at the less than the Value
255
0 - 255
13 DIMMER_CTRL_LEVEL14
Luminance Level 14 Data for Dimmer: Dim
Level 14 at the less than the Value
255
0 - 255
14 DIMMER_CTRL_LEVEL15
Luminance Level 15 Data for Dimmer: Dim
Level 15 at the less than the Value
255
0 - 255
15 DIMMER_AVERAGE_POINT
Luminance Data Avarage Point for Mimmer
4
0 - 16
16 DIMMER_AVERAGE_DATA
Luminance Data Avarage Value for Dimmer
-
-
* Read only
17 DIMMER_LEVEL_AUTO
Current Dimmer Leverl
-
-
* Read only
18 DIMMER_LEVEL_NORMAL
Normal Dimmer Level
12
0 - 15
19 DIMMER_LEVEL_ECO
Eco Dimmer Level
0
0 - 15
20 Lamp check enable
1
0: Lamp Failure Detection OFF (White 50%
Back), 1 : ON (Blue 100% Back)
21 VOLTAGE_LEVEL
Lamp Voltage
Unit: 8bit(Raw Data) * Read only
Group 250 FAN Cntorol
XW55A / XW50A
Normal
Ceiling Normal-
HiLand
Ceiling-
HiLand
0 FAN_TEMP_A_WARNING
Temperature A to judge the Temp. Failure
Outside
39 / 43
40 / 44
34 / 33
34 / 34
30-100
(Memorized)
1 FAN_TEMP_B_WARNING
Temperature B to judge the Temp. Failure
Panel
63 / 66
64 / 67
52 / 52
56 / 58
30-100
(Memorized)
2 FAN_TEMP_C_WARNING
Temperature C to judge the Temp. Failure
Lamp
72 / 75
73 / 76
64 / 64
67 / 66
30-100
(Memorized)
3 FAN_TEMP_B A_WARNING
Temperature B-A to judge the Temp. Failure
Filter Cloggled
100/100 100/100 100/100 100/100
0-100
(Memorized)
4 FAN_TEMP_C
A_WARNING
Temperature C-A to judge the Temp. Failure
Filter Cloggled
100/100 100/100 100/100 100/100
0-100
(Memorized)
5 FAN__SPEED_MONI
Fan Speed Monitor
-
-
-
-
-
* Read only
6 FAN__SPEED_MONI
Fan Speed Monitor
-
-
-
-
* Read only
7 FAN_TEMP_A_MONI
Temp. Sensor Monitor
-
-
-
-
* Read only
8 FAN_TEMP_B_MONI
Temp. Sensor Monitor
-
-
-
-
* Read only
9 FAN_TEMP_C_MONI
Temp. Sensor Monitor
-
-
-
-
* Read only
10 Lamp Mode
Normal/Auto/Eco
1 / 1
0-2
0:Normal, 1: Auto, 2: Eco
11 Fan Ctrl Mode
Normal/Ceiling Switch
0 / 0
0-1
0: Normal, 1: Ceiling
12 Fan Switch
Auto/Max/Min/Manual Switch
0 / 0
0-3
0: Auto
1: Max 2:Min 3: Manual
13 Hi-Land Switch
Hi-Land Switch
0 / 0
0-5
0: Normal Mode , 1: High-land Mode
2˜4: High-land Mode1 ˜ 3, 5: Fixed(13.5V)
14 Safety Switch
FAN Control
0 / 0
0-4
* Test Purpose
15 Fan1 Manual Voltage
Manual Adjustment Mode at FAN_CON-
TROL_SW=3
130 / 130
0-255
16 Fan2 Manual Voltage
Manual Adjustment Mode at FAN_CON-
TROL_SW=3
130 / 130
0-255
17 TEMP_UPWARNING_TIME_A
(OUTSIDE)
Raise Temp Failure Value for X minutes after
Power ON
3 / 3
0-5
18 TEMP_UPWARNING_TIME_B
(PANEL)
Raise Temp Failure Value for X minutes after
Power ON
3 / 3
0-5
19 TEMP_UPWARNING_TIME_C
(LAMP)
Raise Temp Failure Value for X minutes after
Power ON
3 / 3
0-5
20 TEMP_UPWARNING_TIME_B-A
Raise Temp Failure Value for X minutes after
Power ON
3 / 3
0-5
21 TEMP_UPWARNING_TIME_C-A
Raise Temp Failure Value for X minutes after
Power ON
3 / 3
0-5
22 UPWARNING_TEMP_A
(OUT-
SIDE)
Raise Temp Failure Value for a certain
minutes after Power ON
5 / 5
?
23 UPWARNING_TEMP_B (PANEL)
Raise Temp Failure Value for a certain
minutes after Power ON
5 / 5
?
24 UPWARNING_TEMP_C (LAMP)
Raise Temp Failure Value for a certain
minutes after Power ON
5 / 5
?
25 UPWARNING_TEMP_B-A
Raise Temp Failure Value for a certain
minutes after Power ON
5 / 5
?
26 UPWARNING_TEMP_C-A
Raise Temp Failure Value for a certain
minutes after Power ON
5 / 5
?
27 FAN_1_START_SPEED
FAN1 Start Voltage 8V Unit VX10
55 / 45
0-255
28 FAN_2_START_SPEED
FAN2 Start Voltage 8V Unit VX10
65 / 65
0-255
31 FAN_1_COOLING_SPEED
FAN1 Voltage at Power OFF (Fan Mode L1)
100 / 100
0-255
32 FAN_2_COOLING_SPEED
FAN2 Voltage at Power OFF (Fan Mode L1)
100 / 100
0-255
33 FAN_1_TEMPERROR_SPEED
FAN1 Voltage at Temp. Failure
130 / 130
0-255
Summary of Contents for 1 122 356 20
Page 18: ... 18 Optical Parts Disassembly m Optical Unit Top removal M3x8 x5 Optical top Fig 7 ...
Page 53: ... 53 IC Block Diagrams FA5502 P F Control IC621 L3E6100D D A S H LCD Driver IC501 IC531 IC561 ...
Page 54: ... 54 IC Block Diagrams L3E07072 LCD Driver Gamma Correction IC401 M62393 DAC IC3531 ...
Page 55: ... 55 IC Block Diagrams NJW1141 Audio Control IC5001 ...
Page 81: ...KR6 XW55A00 KP6 XW50A00 81 Mechanical Parts List ...
Page 82: ... KR6AD Jun 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...