1
2
3
4
5
6
I-26
SM831148
1. Specifications
1-1 Unit Specifications
Ceiling-Mounted Type
Indoor Unit
TH4272R
Outdoor Unit
C4272R
POWER SOURCE
230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE
Cooling
Capacity * [minimum~muximum]
BTU / h
39,000 [9,500~39,000]
(17˚F)**
BTU / h
Moisture removal (High)
Pints / h
12.6
Air circulation (H / M / L) 230 V
CFM
1100 / 930 / 750
External Static Pressure
in. WG
S.E.E.R. / H.S.P.F. (Region 4)
BTU / Wh
15.6
ELECTRICAL RATINGS
Voltage rating
V
230
208
Available voltage range
V
VAC 187 - 253
Max. Running amperes*
A
21.1
23.3
Power input
W
4,140
4,140
(17˚F)**
W
Back-up Heater
kW
Maximum overcurrent protection (Indoor/Outdoor)
A
15 / 40
Controls
Microprocessor
Low ambient control
Built-in 0˚F
Fan speeds Indoor / Outdoor
3 and Automatic control / Variable
Optional Wired Remote Controller
Optional Wireless Remote Controller
RCS-SH80UA. WL / RCS-BH80UA. WL
Air deflection (Horizontal / Vertical )
/ Automatic (Vertical )
Air filter
Washable, long life (2,500 hr)
Drain pump (Drain connection)
(20A , OD26mm)
Compressor
Rotary(SANYO)
Operation sound
Indoor - Hi/Me/Lo
dB - A
44 / 41 / 37
Outdoor - Hi
dB - A
53
Refrigerant control
Electronic Expansion Valve (MOV)
REFRIGERANT TUBING
Limit of tubing length
ft. (m)
165 (50)
Limit of tubing length at shipment
ft. (m)
10~100 (3~30)
Limit of elevation difference
ft. (m)
Outdoor unit is higher than indoor unit : 100 (30)
between the two units
ft. (m)
Outdoor unit is lower than indoor unit : 50 (15)
Refrigerant tube
Narrow tube
in. (mm)
3 / 8 (6.35)
outer diameter
Wide tube
in. (mm)
5 / 8 (15.88)
Refrigerant amount at shipment
lbs. (kg)
7.94 (3.6) - R410A
DIMENSIONS & WEIGHT
Indoor unit
Outdoor unit
Unit dimensions
Height
in. (mm)
9-7/16 (240)
48-7/16 (1,230 )
Width
in. (mm)
62-1/32 (1,575)
37 (940)
Depth
in. (mm)
26-3/8 (670)
13- 3/8 (340)
Package dimensions
Indoor unit
Outdoor unit
Height
in. (mm)
12-15/32 (317)
52-3/8 (1,330 )
Width
in. (mm)
66-1/16 (1,678)
39- 31/32 (1,015)
Depth
in. (mm)
31-1/16 (789)
16- 3/32 (409)
Net weight
lbs. (kg)
84 (38)
220 (100)
Shipping weight
lbs. (kg)
97 (44)
240 (109 )
Shipping volume
cu.ft. (m 3 )
14.8 (0.420)
19.5 (0.552 )
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
FEATURES
MODEL No.
RCS-SH80UG / RCS-TM80BG
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
Summary of Contents for 000 BTU Ductless Single Zone Mini-Split Wall-Mounted Heat Pump
Page 2: ......
Page 77: ...1 2 3 4 5 6 I 73 SM831148 1 Specifications 1 4 Dimensional Data B Outdoor Unit CH4272R C4272R ...
Page 118: ......
Page 128: ...1 2 3 4 5 6 III 10 SM831148 3 Electrical data Wall Mounted Type KH2672R ...
Page 129: ...III 11 SM831148 3 Electrical data 1 2 3 4 5 6 Wall Mounted Type KH2672R Schematic Diagram ...
Page 133: ...III 15 SM831148 3 Electrical data 1 2 3 4 5 6 Wall Mounted Type KHH2672R Schematic Diagram ...
Page 135: ...III 17 SM831148 3 Electrical data 1 2 3 4 5 6 3 2 Outdoor Units CH2672R Schematic Diagram ...
Page 137: ...III 19 SM831148 3 Electrical data 1 2 3 4 5 6 3 2 Outdoor Units C2672R Schematic Diagram ...
Page 143: ...III 25 SM831148 3 Electrical data 1 2 3 4 5 6 3 2 Outdoor Units CH4272R Schematic Diagram ...
Page 145: ...III 27 SM831148 3 Electrical data 1 2 3 4 5 6 3 2 Outdoor Units C4272R Schematic Diagram ...
Page 146: ......