CAUTION
!
Use the UPS following the instructions in this instruction manual. Improper use may result in an electric shock, bodily
injury, and/or a fire.
The following describes the basic steps for the basic operation of providing power supply backup to load equipment such as a PC.
For details on UPS functions and settings, such as control panel setting menu items, how to use optional devices, and external
transmission signals, see “5. Using the UPS (Application)”.
4
4
.
.
1
1
P
P
r
r
e
e
p
p
a
a
r
r
a
a
t
t
i
i
o
o
n
n
Step
Operation
Remarks
1
1
Check the following items:
1-1 Is the exterior of the UPS in any way damaged or deformed?
1-2 Is the outlet that connects the UPS a dedicated outlet for one UPS?
1-3 Is the outlet of the utility power that connects the UPS a two-pole outlet with
ground?
If there is any damage such as a dent or
deformation that may affect the UPS interior,
contact your sales representative or SANYO
DENKI. Do not use the UPS as is. Doing so is
dangerous.
Do not connect the UPS to any outlet other than
that specified. Doing so may result in abnormal
heat generation or a fire.
Prepare a UPS dedicated outlet so as to not
overload the electrical circuit.
When the outlet does not have a ground
terminal, ground construction by a certified
electrician is required. Request construction
through your sales representative. Do not use
the UPS in an environment where it cannot be
grounded.
Attach the conversion adapter in the correct
orientation. Do not attach the adapter in the
reverse orientation.
2
2
Prepare the supplied input cable.
Be sure to use the supplied cable. When a cable
other than the specified cable is used, smoke
and/or a fire may occur.
3
3
Connect the input cable to the “INPUT” inlet on the back of the UPS.
Fully insert the plug so that the plug is not loose.
Back of UPS
From here on, the 100 V model UPS is described as
an example. Perform the same operation with the
200 V model UPS as well.
FE
TOTAL OUTPUT MAX.800W 10A
Connect the input cable
to the “INPUT” inlet on
the back of the UPS.
Be sure to connect
to ground terminal
Conversion adapter
When outlet with
ground terminal
Reverse orientation
No ground terminal
100 V
When the outlet is a two-pole outlet
(an outlet without a ground pole),
use the conversion adapter (option).
Two-pole outlet with ground
15A (NEMA 5-15R)
200 V
Two-pole outlet with ground
10A (IEC-C13)
100 V
200 V