Automatic Voltage Regulators

increase low or decrease high voltage to a computer 
safe 110/120 volts. The AVR automatically provides 
battery back-up power if line voltage drops below 90 
volts or exceeds 140 volts.

AVR

INCONSISTENT

UTILITY POWER

CONSISTENT 

SAFE POWER

Min

V

ESTIMATE RUN_TIME

INPUT

LOAD CAPACITY

BATT. CAPACITY

OUTPUT

BATTERY

A.V.R

FAULT

NORMAL

NORMAL

SILENT

OVER

LOAD

100

IN

OUT

UNPACKING

Inspect the UPS upon receipt. The box should contain the following:
(1) UPS unit; (1) User’s manual; (1) PowerPanel

®

 Personal Edition software CD; (1) USB device cable; (1) Telephone cable; (1) Warranty 

registration card; (1) Coaxial Cable 

OVERVIEW

The  CP1285AVRLCD  provides  automatic  voltage  regulation  for  inconsistent  utility  power.  The 
CP1285AVRLCD features 1080 Joules of surge protection, and provides battery backup during power 
outages.   The  CP1285AVRLCD  ensures  consistent  power  to  your  computer  system  and  its  included 
software  will  automatically  save  your  open  files  and  shutdown  your  computer  system  during  a  utility 
power loss.

AUTOMATIC VOLTAGE REGULATOR

The CP1285AVRLCD stabilizes inconsistent utility power.  The incoming utility power may be damaging 
to  important  data  files,  but  with Automatic  Voltage  Regulation,  the  computer  will  not  experience  damaging  voltage  levels.   An Automatic 
Voltage  Regulator  automatically  increases  low  or  decreases  high  voltage  to  a  consistent,  computer  safe  110v/120v.   The  unit’s  powerful 
sealed lead-acid batteries will provide power only if the incoming voltage drops below 90v or increases above 140v.

HARDWARE INSTALLATION GUIDE

1. Your new UPS may be used immediately upon receipt.  However, recharging the batteries for at least 16 hours is recommended to ensure 

that  the  battery’s  maximum  charge  capacity  is  achieved.   A  loss  of  charge  may  occur  during  shipping  and  storage.    To  recharge  the 
batteries, simply leave the unit plugged into an AC outlet.  The unit will charge in both the ON as well as the OFF position.

2. With the UPS unit off and unplugged, connect your computer, monitor, and any externally powered data storage device (Zip drive, Jazz 

drive, Tape drive, etc…) into the battery power supplied outlets.  Plug your peripheral equipment (printer, scanner, speakers) into the full-
time surge protection outlets.  

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum or other large electrical 

device into the UPS.  The power demands of these devices will overload and possibly damage the unit.

3. To  surge  protect  a  network  connection,  connect  a  network  cable  from  the  wall  jack  outlet  to  the  IN  jack  of  the  UPS. Then  connect  a 

network cable from the OUT jack on the UPS to the network device.

4. Plug the UPS into a 2 pole, 3 wire grounding receptacle (wall outlet).  Make sure the wall branch outlet is protected by 

a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. refrigerator, copier, etc…).  
The warranty prohibits the use of extension cords, outlet strips, and surge strips.

5. Press the power switch to turn the unit on.  The power on indicator light will illuminate and the unit will “beep” once.
6. If an overload is detected, an audible alarm will sound and the unit will emit one long beep.  To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.  Wait 10 seconds.  Make sure the circuit breaker is depressed and 
then turn the UPS on.

7. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
8. To store your UPS for an extended period, cover it and store with the battery fully charged.  While in storage recharge the battery every 

three months to ensure battery life.

CP1285AVRLCD

User’s Manual

K01-0000018-00

(SAVE THESE INSTRUCTIONS)

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the 
unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.  (Please see specifications for acceptable temperature and humidity range).

CAUTION! 

 To reduce the risk of electric shock, do not remove the cover except to service the battery.  No user serviceable parts inside 

except for battery.

CAUTION!  

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.

CAUTION!  

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.  Do not plug into an outlet that is not 

grounded.  If you need to de-energize this equipment, turn off and unplug the unit.

CAUTION!  

To avoid electrical shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a 

computer component.

CAUTION!  

To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in 

accordance with the national Code, ANSI / NFPA 70.

DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT!  

CyberPower Systems does not sell products for life support or medical 

applications.    DO  NOT  use  in  any  circumstance  that  would  affect  operation  or  safety  of  any  life  support  equipment  or  with  any  medical 
applications or patient care.

DO  NOT  USE  WITH  OR  NEAR  AQUARIUMS!   

To  reduce  the  risk  of  fire  or  electric  shock,  do  not  use  with  or  near  an  aquarium.   

Condensation from the aquarium can cause the unit to short out.

DO NOT USE WITH LASER PRINTERS!  

The power demands of these devices will overload and possibly damage the unit.

DESCRIPTION

1    Power Switch 

Used as the master on/off switch for equipment connected to the battery power supplied outlets.

2    Power On Indicator

This  LED  is  under  the  power  switch.  It  illuminates  when  the  utility  condition  is  normal  and  the  UPS  outlets  are 
providing power, free of surges and spikes. 

  3    LCD Module Display.

High resolution and intelligent LCD display shows all the UPS information with icons and messages. For more information please check the 
“Definitions for Illuminated LCD Indicators” section.  

  4    LCD Display Toggle/Selected Switch

The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and Estimated Run 
Time. The toggle frequency is set to one time per second. Holding the switch for more than two seconds while running 
on battery will silence the buzzer.  

  5    Battery and Surge Protected Outlets

The  unit  has  four  battery  powered/surge  protected  outlets  for  connected  equipment  and  ensures  temporary 
uninterrupted operation of your equipment during a power failure.

  6    Full-Time Surge Protection Outlets

The unit has four always on surge suppression outlets.

  7    Electrical Wiring Fault Indicator

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.  If 
this is illuminated, user is advised to disconnect all electrical equipment from the outlet and have an electrician check to ensure the outlet is 
properly wired. The unit will not provide surge protection without being plugged into a grounded and properly wired wall outlet.

  8    Communication Protection Ports

Communication protection ports will protect any standard modem, fax , telephone line, broadband network or Ethernet connection.

  9    Circuit Breaker

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection. 

 10    Serial/USB Ports to PC

The ports allow connection and communication from the USB or DB-9 serial port on the computer to the UPS unit.  The USB port will 
communicate with PowerPanel

®

 Personal Edition and the  DB-9 port is for use with a serial cable and the Microsoft

®

 UPS Service.

Note: Only one of these two ports can be used to communicate with your computer at one time.
Note: To install PowerPanel

®

 Personal Edition Software the computer will need Microsoft

®

 Internet Explorer 5.0 or higher installed.

Note: If using the Serial Port please read the directions to configure the Microsoft UPS service on our website 

http://www.cyberpowersystems.com/ups_service.asp

 . If you need a serial cable please contact CyberPower technical support at

[email protected]

 

 11    Coax/Cable/DSS Surge Protection

The Coax/Cable/DSS surge protection ports will protect any cable modem, CATV converter, or DSS receiver.

 12    Outlets Designed for AC Adapters

The unit has four outlets spaced to allow AC power adapter blocks to be plugged into the UPS without blocking adjacent outlets.

CAUTION! 

Read  and  follow  the  IMPORTANT  SAFETY  INSTRUCTIONS  before  servicing  the  battery.    Service  the  battery  under  the 

supervision of personnel knowledgeable of batteries and their precautions.

CAUTION! 

Use only the specified type of battery.  See your dealer for replacement batteries.

CAUTION! 

The  battery  may  present  a  risk  of  electrical  shock.    Do  not  dispose  of  battery  in  a  fire  as  it  may  explode.  Follow  all  local 

ordinances regarding proper disposal of batteries.  Almost any retailer that sells lead-acid batteries collects used batteries for recycling, as 
required by most state laws.

CAUTION! 

Do not open or mutilate the batteries.  Released electrolyte is harmful to skin and eyes and may be toxic.

CAUTION! 

A battery can present a high risk of short circuit current and electrical shock.  Take the following precautions before replacing the 

battery:
1.Remove all watches, rings or other metal objects.
2.Only use tools with insulated handles.
3.Do not lay tools or metal parts on top of battery or any terminals.
4.Wear rubber gloves and boots.
5.Determine if the battery is inadvertently grounded. If grounded, remove the source of ground. 

CONTACT WITH GROUNDED BATTERY

   CAN RESULT IN ELECTRICAL SHOCK!

IMPORTANT SAFETY WARNINGS

INSTALLING YOUR UPS SYSTEM

BASIC OPERATION

TROUBLE SHOOTING

  1. Turn off and unplug all connected equipment.
  2. Turn the UPS off and unplug it from the AC power source.
  3. Turn the UPS upside down.
  4. Remove the retaining screw.
  5. Slide the battery compartment cover (front panel) completely off of the unit.
  6. Remove the batteries from the compartment.
  7. Disconnect the battery wires from the batteries.
  8. Install the replacement batteries by connecting the red wire and black wire to the same color 

wires from the battery pack.

  9. Put the batteries back into the compartment.
10. Slide back the battery compartment cover and tighten the retaining screw. 
11. Recharge the UPS for 8-16 hours to fully charge the battery. 

The LCD display indicates a variety of UPS 

operational conditions. All descriptions apply 

when the UPS is plugged into an AC outlet 

and turned on or when the UPS is on battery.  

INPUT  voltage  meter: 

This  meter  measures  the  AC  voltage  that  the  UPS  system  is 

receiving from the utility wall outlet. The UPS is designed, through the use of automatic 
voltage  regulation,  to  continuously  supply  connected  equipment  with  stable,  110/120 
output voltage. In the event of a complete power loss, severe brownout, or over-voltage, 
the  UPS  relies  on  its  internal  battery  to  supply  consistent  110/120  output  voltage.  The 
INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.

OUTPUT voltage meter: 

This meter measures, in real time, the AC voltage that the UPS 

system is providing to the computer, such as normal line mode, AVR mode, and battery 
back up mode.

Note: The OUTPUT voltage meter shows the status of the battery back up outlets.

ESTIMATE RUN TIME: 

This displays the run time estimate of the UPS with the current 

battery capacity and load.  

NORMAL icon: 

This icon appears when the UPS is working under normal conditions.

BATTERY icon: 

During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to 

indicate the UPS is operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously (and the 
BATT.CAPACITY meter shows one 20% capacity segment shaded) to indicate the UPS’s batteries are nearly out of power. You should save 
files and turm off your equipment immediately.

AVR (Automatic Voltage Regulator) icon:

 This icon appears whenever your UPS is automatically correcting low AC line voltage without 

using battery power. This is a normal, automatic operation of your UPS, and no action is required on your part. 

SILENT MODE icon:

This icon appears whenever the UPS is in silent mode. The buzzer does not  beep during silent mode until the battery 

reaches low capacity.

OVER LOAD icon: 

This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, 

unplug some of your equipment from the battery-supplied outlets until the icon turns off and the alarm stops.

FAULT icon: 

This  icon  appears  if  there  is  a  problem  with  the  UPS.  Contact  CyberPower  Systems  at  [email protected]  for 

further help and support.

BATT.  CAPACITY  meter: 

This  meter  displays  the  approximate  charge  level  (in  20%  increments)  of  the  UPS’s  internal  battery.  During  a 

blackout or severe brownout, the UPS switches to battery power, the BATTERY icon appears, and the charge level decreases.

LOAD CAPACITY meter: 

This meter displays the approximate output load level (in 20% increments) of the UPS’s battery outlets.

REPLACING THE BATTERY

DEFINITIONS FOR ILLUMINATED LCD INDICATORS

REMINDER: 

Batteries  are  consider  HAZARDOUS  WASTE  and  must  be  disposed  of  properly.    Almost  any  retailer  that  sells  lead-acid 

batteries collects used batteries for recycling, as required by most state laws.

Additional troubleshooting information can be found at

www.cyberpowersystems.com/support.htm

Problem

Possible Cause

Solution

Full-time surge protection outlets 

stop providing power to equipment. 

Circuit breaker button is projecting 

from the side of the unit.

Circuit breaker has 

tripped due to an 

overload.

Turn the UPS off and unplug at least one piece of equipment.  

Wait 10 seconds, reset the circuit breaker by depressing the 

button, and then turn the UPS on.

The UPS does not perform 

expected runtime.

Recharge the battery by leaving the UPS plugged in.

Contact CyberPower Systems about replacement batteries at 

[email protected]

Battery is slightly worn out.

Battery not fully charged.

The UPS will not turn on.

The on/off switch is designed 

to prevent damage by rapidly 

turning it off and on.

Turn the UPS off.  Wait 10 seconds and then turn the UPS on.

The unit is not connected to an 

AC outlet.

The unit must be connected to a 110/120v 60Hz outlet.

The battery is worn out.

Contact CyberPower Systems about replacement batteries at 

[email protected]

Mechanical problem.

Contact CyberPower Systems at 

[email protected]

PowerPanel

®

 Personal Edition is 

inactive (all icons are gray).

The USB cable is not 

connected.

Connect the USB cable to the UPS unit and an open USB port 

on the back of the computer.  You must use the cable that 

came with the unit.

The USB cable is connected 

to the wrong port.

Check the back of the computer for an additional USB port.  

Move the cable to this port.

The unit is not providing 

battery power.

Shutdown your computer and turn the UPS off.  Wait 10 

seconds and turn the UPS back on.  This should reset the unit.

TO REPLACE THE BATTERY