Instruction Manual for R Max
1-888-726-8869
www.sanuvox.com
STEP 5
STEP 6
STEP 7
STEP 8
STEP 9
5. Carefully slide the new
UV lamp
out from the cardboard sleeve. Be sure
to wear the
cotton gloves
(included) guaranteeing a clean lamp free
from fingerprints. Fingerprints on the lamp will negatively impact the UV
output of the lamp.
6. While holding the porcelain end-cap (with 4 pins) in the clamp, carefully
push the white connector onto the four pins. The connector will fit into
position.
NOTE:
Too much force applied from the opposite end-cap may break
the lamp.
7. Slide the UV lamp porcelain end-cap (with 4 pins) in the aluminum
tube of the unit, then through the clamp.
8. Once the UV lamp is inserted, release the clamp to fix the lamp in place.
9. Once the new UV lamp is installed, replace the turbulator on
top of the reflecting chamber, and replace R Max into duct.
Then, reset your product and its lamp timer (see page 9).