8
2
Mount the Wall Plate
Solid concrete or concrete block
concrete only
13 mm
(1/2 in.)
10 mm
(3/8 in.)
For assitance in determining wall plate location, see Height Finder at SANUS.com.
[03]
002862.eps
75 mm
(3 in.)
[09]
Drill pilot holes as illustrated.
CAUTION:
To avoid potential injuries or property damage:
Ù
Pilot holes MUST be drilled to a depth of 75 mm (3 in.) using a
10 mm (3/8 in.) diameter drill bit.
Ù
Never drill into the mortar between blocks.
Insert lag bolt anchors [09].
CAUTION:
To avoid potential injuries or property damage be
sure the anchors [09] seat flush with the concrete surface.
Tighten the lag bolts [07] only until the washers [08] are pulled
firmly against the wall plate [03].
CAUTION:
Improper use could reduce the holding power of
the lag bolt. To avoid potential injuries or property damage DO NOT
over-tighten the lag bolts [07].
[03]
[08]
[07]
Level wall plate and mark the hole locations.
CAUTION:
Avoid potential personal injuries and property
damage!
Ù
Mount the wall plate [03] directly onto the concrete surface.
Ù
Minimum solid concrete thickness: 203mm (8 in.).
Ù
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in.).
Ù
Minimum horizontal space between fasteners: 40.6 cm (16 in.).
Summary of Contents for 793795521965
Page 11: ...11...