SAS-to-SATA II RAID Subsystem
Installation and Configuration Manual
60
4.5 System Controls
4.5.1 System Configuration
To set the RAID subsystem system configuration options, click the
System Config
link under the
System Controls
menu. The System Configuration screen will be
shown. Set the system configuration option as needed.
System Beeper Setting:
This option is used to Disabled or Enable the subsystem’s RAID controller alarm beeper.
Background Task Priority:
The Background Task Priority indicates how much time and system resource the RAID
controller devotes to a background task, such as a rebuild operation. The RAID subsystem
allows user to choose the background task priority (High 80%, Medium 50%, Low 25%,
and Ultra Low 5%) to balance between background task process and Volume Set
access. For high RAID subsystem performance, specify a low value.
Terminal Port Configuration:
Baud Rate setting values are 1200, 2400, 4800, 9600, 19200, 38400, 57600, and
115200. Use 115200 for the RAID subsystem terminal port speed setting.
Stop Bits values are 1 and 2. Use 1 for the RAID subsystem Stop Bit setting.
NOTE: Parity value is fixed at None. Data Bits value is fixed at 8 bits.