64
Description
Possible Cause
Remedy
Remarks
5.
E11 error code displayed
Over Primary supply
(input) voltage at primary
capacitors is exceeded
for one second.
Primary supply voltage is
greater than the nominal
voltage plus 10%.
Have an Accredited SanRex
Service Agent or a qualified
electrician check the Primary
voltage.
Weld current ceases.
Buzzer sounds constantly.
Error code E11 automatically will
reset when the voltage reduces.
6.
E12 error code displayed
Under mains supply
(input) voltage primary
capacitors is reduced for
one second.
Mains supply voltage is
down to a dangerously low
level.
Have an Accredited SanRex
Service Agent or a qualified
electrician check the Mains
voltage.
Weld current available.
Buzzer sounds intermittently.
Error code E12 will automatically
reset when the voltage increases.
7.
E14 error code displayed
Under mains supply
(input) voltage warning
primary capacitors is
reduced for one second.
Mains supply voltage is less
than the nominal operating
voltage less 10%.
Have an Accredited SanRex
Service Agent or a qualified
electrician check the Mains
voltage.
Weld current ceases.
Buzzer sounds constantly.
Error code E12 will automatically
reset when the voltage increases.
8.
E33 error code displayed
Water cooled torch
abnormality detected.
Insufficient water pressure is
detected when water pressure
sensor circuit is enabled.
Check that water circulator is
turned on and water is
flowing.
Weld current ceases.
Buzzer sounds constantly.
Error code E33 will automatically
reset when adequate water pressure is
established or circuitry is disabled.
9.
E81 error code displayed
Wrong Primary supply
(input) voltage connected
When 3 phase machine is
first turned on with the
wrong Primary supply
(input) voltage connected.
Have an Accredited SanRex
Service Agent or a qualified
electrician check the Mains
voltage.
No weld current is available.
Buzzer sounds constantly.
Switch machine off.
10.
E82 error code displayed
Link switch plug not
connected
Link switch plug not
connected.
Have an Accredited SanRex
Service Agent check
connector plug on input PCB.
No weld current is available.
Buzzer sounds constantly.
Switch machine off.
Summary of Contents for SANARG 200AP
Page 2: ......
Page 4: ......
Page 8: ......
Page 24: ...24 PAGE LEFT INTENTIONALLY BLANK ...
Page 35: ...35 Figure 3 2 Electrical Input Connections 200AP ...
Page 60: ...60 PAGE LEFT INTENTIONALLY BLANK ...
Page 66: ...66 PAGE LEFT INTENTIONALLY BLANK ...
Page 79: ...79 PAGE LEFT INTENTIONALLY BLANK ...
Page 80: ...80 10 1 INTERCONNECT DIAGRAM 200AP ...
Page 81: ...81 ...
Page 82: ...82 10 2 EXPLODED VIEW 200AP ...
Page 83: ...83 ...
Page 84: ...84 PAGE LEFT INTENTIONALLY BLANK ...
Page 89: ...PAGE LEFT INTENTIONALLY BLANK ...