6.1
STICK WELDING
•
Connect work lead to negative terminal
•
Connect electrode lead to positive terminal
•
Switch machine on
•
Set
AC
or
DC
weld current. If
AC
is selected then set
AC FREQ
to 60Hz &
WAVE BALANCE
to 50%.
•
Set Contactor.
•
Connect remote control device if required
Use the Scroll Buttons to move to the parameter to be set. The LED will show
which function is being adjusted on the weld sequence graph. Use the control knob
to adjust each parameter.
•
Set
HOT START
•
Set
WELD
current
•
Commence welding