Parameter
Description
PEAK CUR.
(WELD)
This parameter sets the PEAK weld current when in
PULSE
mode
This parameter sets the TIG WELD current in
STD
,
SLOPE
,
REPEAT
and
SPOT
modes when
PULSE
is off. This parameter also sets the STICK
weld current.
BASE
(Background
Current)
This parameter sets the Background current when in Pulse TIG mode.
SPOT TIME
This parameter sets the duration of the
SPOT TIME
in
HF TIG
mode only
PULSE WIDTH
This parameter sets the percentage on time of the
PULSE FREQUENCY
for PEAK weld current when the
PULSE
is on.
PULSE FREQ.
This parameter sets the
PULSE FREQUENCY
when the
PULSE
is on.
AC
FREQUENCY
This parameter operates in AC mode only and is used to set the frequency
for the AC weld current.
WAVE
BALANCE
This parameter is used for aluminium AC TIG mode and is used to set the
penetration to cleaning action for the AC weld current. Generally
WAVE
BALANCE
is set to 50% for AC
STICK
welding. The
WAVE BALANCE
control changes the ratio of penetration to cleaning action of the AC TIG
welding arc. Maximum weld penetration is achieved when the
WAVE
BALANCE
control is set to 10%. Maximum cleaning of heavily oxidised
aluminium or magnesium alloys is achieved when the
WAVE BALANCE
control is set to 65%.
DOWN SLOPE
This parameter operates in TIG modes only and is used to set the time for
the weld current to ramp down, after the torch trigger switch has been
pressed, to
CRATER CUR.
This control is used to eliminate the crater that
can form at the completion of a weld.
CRATER CUR.
This parameter operates in
SLOPE
or
REPEAT
(4T) TIG modes only and
is used to set the finish current for TIG. The CRATER Current remains on
until the torch trigger switch is released after it has been depressed.
POST-FLOW
This parameter operates in TIG modes only and is used to adjust the post
gas flow time once the arc has extinguished. This control is used to
dramatically reduce oxidation of the tungsten electrode.
WAVE BALANCE=10%
Maximum Penetration and
reduced cleaning
WAVE BALANCE=50%
Balanced with 50% penetration
and 50% cleaning
WAVE BALANCE=65%
Maximum Cleaning and
reduced penetration
10%
50%
65%
90%
50%
35%
(+ )
(+ )
(+ )
(-)
(-)
(-)
Summary of Contents for SANARG 200AP
Page 2: ......
Page 4: ......
Page 8: ......
Page 24: ...24 PAGE LEFT INTENTIONALLY BLANK ...
Page 35: ...35 Figure 3 2 Electrical Input Connections 200AP ...
Page 60: ...60 PAGE LEFT INTENTIONALLY BLANK ...
Page 66: ...66 PAGE LEFT INTENTIONALLY BLANK ...
Page 79: ...79 PAGE LEFT INTENTIONALLY BLANK ...
Page 80: ...80 10 1 INTERCONNECT DIAGRAM 200AP ...
Page 81: ...81 ...
Page 82: ...82 10 2 EXPLODED VIEW 200AP ...
Page 83: ...83 ...
Page 84: ...84 PAGE LEFT INTENTIONALLY BLANK ...
Page 89: ...PAGE LEFT INTENTIONALLY BLANK ...