31/36
2) Parameter list
Each time the Vol
▲
key is pressed, the parameter display switches in the descending order of the
following table. Each time the Vol
▼
key is pressed, the parameter display switches in the ascending order.
No.
Function
Description
Setting range
Default value
operation pattern
1
2
3
4
n
A
0A
ON delay timer
in2 Input ON delay timer
0.0-9.9
0.0
〇
〇
〇
0b
OFF delay timer
in2 Input OFF delay timer
0.0-9.9
0.0
〇
〇
〇
0C
Soft start
Output soft start timer
0.2-9.9
--: Invalid
--
〇
〇
〇
0d
Soft stop
Output soft stop timer
0.2-9.9
--: Invalid
--
〇
〇
〇
0E
Start delay timer Output start delay timer
0.0-9.9
0.0
〇
〇
〇
0F
Stop delay timer OUT4 Output stop delay
timer
0.0-9.9
0.0
〇
〇
〇
0n
Parts shortage
timer
in2 Input parts shortage
detection
0-99
10
〇
〇
〇
0L
Remote Unit
setting
oF: The remote unit is invalid.
on: The remote unit is valid.
oF/on
oF
〇
〇
-
0o
Frequency
tracking cycle
Setting of frequency
changing cycle
0.1-9.5
1.0
〇
〇
〇
0P
PI control gain
Setting of the speed of
output response to vibration
change when the
constant-amplitude control
is in process
1 (slow)
⇔
9 (fast)
1-9
9
〇
〇
〇
0q
Vibration sensor
setting
Use of vibration sensor in the
constant amplitude control
Valid/Invalid
oF/on
on
〇
〇
-
0r
Search setting
Use of vibration sensor in
automatic tuning of frequency
Valid/Invalid
oF/on
oF
〇
〇
-
05
Adjusting
frequency range
Setting of the search range
when the automatic frequency
tuning is in process
L:50-180Hz
C:160-280Hz
H:260-400Hz
AL:50-400Hz
L
〇
〇
-
06
in1 setting
in1 Input logic
hi: Operation with
the contact
“Close”
Lo: Operation
with the contact
“Open”
Lo
〇
〇
-
07
in2 setting
in2 Input logic
hi
〇
〇
-
08
OUT2 setting
Setting of OUT2 Output
function
AL/Er
AL
〇
〇
-
Display pattern No. Backup display pattern No.
PAt1 PAt2 PAt3 PAt4
〇
-
% display
Output voltage backup display
0.0 0.0 0.0 0.0
〇
-
Hz display
Frequency backup display
240.0 240.0 240.0 240.0
〇
-
Version information Program version
V2xx
〇
-
io mode No. display io01: With overflow stop
io02: Without overflow stop
io03: 4 patterns [in2:Lo fixed]
io04: 4 patterns [in2:hi fixed]
io01/io02
io03/io04
io01
〇
-
0u
Amplitude control
setting
0: Constant voltage
1: Constant-amplitude and
automatic frequency
tracking
2: Constant-amplitude
0-2
0
〇
〇
-
Change during operation:
〇
…
Enabled,
…
Disabled
Display according to mode:
〇
…
Enabled,
-…
Disabled
Display
according to
the operation
mode
Change
during
operation