19 / 32
10.0
20.0
SAVE
20.0
20.0
n
A
20.
20.
※To next page
※
From previous page
Func key
Freq
▲▼
keys
Set key
Vol
▲▼
keys
Raise the output%
until the required
speed is achieved.
When 0u=0,
⇒ Only the AUTO lamp lights up.
When 0u=1,
⇒ Both the AUTO lamp and the AAC lamp light up.
The above status of lamp indicates that the mode
has been switched to the operation mode.
⑤
Switching from the adjustment mode to the operation mode
Press the
Set key long
for 2 sec.
Operation mode
・
The operation is performed based on the value
saved in the adjustment mode.
When u=1, the feedback control is performed.
・
Magnification change for vibration quantity can
be adjusted. (Refer to
⑥
-C)
< When 0u=0>
※Now, the vibration adjustment is completed.
< When 0u=1>
Blinking
“SAVE” is an operation to save the frequency
and the output% to the main unit of the
controller.
When the display of
“SAVE”
blinks, is means
that the data has been saved.
(When 0u=1 and 2, the vibration quantity is
also saved.)
If the main unit of the Controller is powered
OFF without the SAVE operation, the data will
not be saved.
Therefore, be sure to perform the SAVE
operation when the feeder is in operation.