13 / 32
2)
Operation keys
No
Name
Description
A
ON/OFF key
Performs forced operation and forced stopping.
B
Func key
Brief pressing: Switches the function setting.
Long pressing: Switches the mode between the parameter mode and the
normal mode.
C
Set key
Brief pressing: Changes and locks the data.
Long pressing: Saves the data (voltage, frequency, vibration quantity).
D
Vol
▲
key
Normal mode: When pressed briefly when the frequency is being displayed,
the frequency display switches to the voltage display.
“A” mode; The voltage cannot be changed.
When the magnification change setting is uLoc, the
speed magnification can be changed.
“n” mode; Adjusts the output voltage.
Parameter mode: Selects the parameter No.
E
Vol
▼
key
F
Freq
▲
key
Normal mode: When pressed briefly when the voltage is being displayed,
the voltage display switches to the frequency display.
“A” mode; The frequency cannot be changed.
“
n
”
mode; Adjusts the frequency.
Function setting is in display: Each function setting can be changed.
Parameter mode: Changes the parameter data.
G
Freq
▼
key
*Long pressing: Continually press the key for 2 sec.
7-2.
Display Mode
1)
Normal mode
Displays and sets the output voltage, the frequency and the function setting on the data display
area.
Upon turning ON the power supply, this display appears.
A mode
⇒
Displays the output voltage and the frequency, and displays and sets the function
setting.
n mode
⇒
Displays and sets the output voltage and the frequency, and saves their data.
Displays and sets the function setting.
2)
Parameter mode (Pilot lamp
⑤
FUNC is ON.)
Shows and sets the parameter on the data display. (Details
⇒
P.26
)
Depending on the operation mode, the parameter that can be set is differing.
A mode
⇒
Displays and sets the parameter that needs to be changed during operation.
n mode
⇒
Displays and sets all parameters.
To switch the display mode, press the Func key long for 2 sec.
Regardless of the display mode, operation and stopping through the panel and under the external
control is enabled.