7 / 32
5. Input/Output Connections
1) Vibratory feeder drive connection
Confirm that the power supply is in the OFF status. Then, connect the output cable of the
controller to the feeder cable of the electromagnetic feeder.
The connector wire colors should be identified as follows:
※
1:
Do not connect to a piezo feeder.
※
2: Do not operate with no load.
※
3: Be sure to ground the feeder.
2) Power source connection
Connect the power cable to the single-phase power source.
Do not turn ON the power supply until the whole wiring work is completed.
※
1: Be sure to connect to the utility power source.
※
2:
Adjust the input voltage to the rated voltage of the vibrator.
※
3: Be sure to ground the controller.
※
4:
Do not perform the ON/OFF control on the input power supply side.
3) Vibration sensor connection
Connect the vibration sensor to perform constant amplitude control.
(1)
Mounting of vibration sensor
Fix the vibration sensor (Accessory) onto the top of the vibrating body of the feeder or the
horizontal surface of the vibration part of the bowl chute or the like (in such a way that the
arrow printed on the sensor looks horizontal) with M4 bolt. In mounting the vibration sensor,
be careful not to allow the vibration sensor body and the feeder cable to interfere with other
parts. In determining the mounting direction of the vibration sensor, it should be noted that the
lead wire side of the vibration sensor corresponds to the parts transfer direction.
100-120VAC
200-240VAC
Lead wire
Feeder cable
Black
White
Electromagnetic
feeder
Mounting of
vibration sensor
Horizontal surface of
vibration part
Overflow sensor
Vibration sensor (KS-3)
[Accessory]
Parts transfer direction