![Sanken SAMCO-NS Series Instruction Manual Download Page 51](http://html1.mh-extra.com/html/sanken/samco-ns-series/samco-ns-series_instruction-manual_3998598051.webp)
-50-
Code
Function Name
Data Content
Setting
resolution
Factory
preset
2304
LCD
‘s
2
nd
screen
display parameters
setting
1
:
No unit
(
Multiple of F1203
)
2
:
Output voltage [V]
3
:
DC voltage[V]
4
:
Active power [kW]
5
:
Apparent power [kVA].
6
:
Radiator temperature [
℃
]
7
:
Command speed [rpm]
8
:
PID1 feedback value [Hz]
9
:
PID2 feedback value [Hz]
10
:
VRF analog input value [Hz]
11
:
V/I analog input value [Hz]
14
:
Partial execitation current [A]
15
:
Partial torque current [A]
17
:
Set pressure[MPa]
18
:
Command pressure[MPa]
19
:
Feedback pressure[MPa]
20
:
Regular pump to switch calculating time
29
:
Command frequency [Hz]
35
:
Detection speed [rpm]
44
:
Target frequency [Hz]
45
:
Output frequency [Hz]
1
2
2306
LCD backlight out
time
0
:
off
1
~
600
:
the time until it goes off
999
:
Normally on
1min.
10