![Sanken SAMCO-NS Series Instruction Manual Download Page 39](http://html1.mh-extra.com/html/sanken/samco-ns-series/samco-ns-series_instruction-manual_3998598039.webp)
-38-
Code
Function Name
Data Content
Setting
resolution
Factory
preset
1422
Reference frequency
for pulse input
1000
~
60000
1Hz
1000
1423
Effective number of bits
for VRF detection
位数
7
~
10bit
1bit
10
1424
Effective number of bits for
V/I detection
7
~
10bit
1bit
10
1501
Internal analog output
function
1
0
:
No Function
1
:
Set frequency [Hz]
2
:
Output frequency [Hz]
3
:
PID1 feedback value [Hz]
4
:
PID2 feedback value [Hz]
5
:
Output current [A]
6
:
Output voltage [V]
7
:
DC voltage [V]
8
:
Radiator temperature [
℃
]
9: Load factor [%] (electric thermistor
integrated value)
10: Load factor [%]
(
Ratio to rated current
)
11
:
VRF analog input value [V]
12
:
V/I analog input value [V]
14
:
Speed [rpm]
15
:
Active power [kW]
16
:
Apparent power [kVA]
17
:
PID1 command value [Hz]
18
:
PID1 input deviation value [Hz]
19
:
PID2 command value [Hz]
20
:
PID2 input deviation value [Hz]
24
:
External PID1 output value [Hz]
25
:
External PID2 output value [Hz]
35
:
command frequency [Hz]
36
:
command torque [%]
1
0
1502
Internal analog output
Coefficient 1
0
~
20
0.01
1
1503
Internal analog output
Bias
1
0
~
±10.0V
0.1V
0