![Sanken NS-4A003-B Instruction Manual Download Page 37](http://html1.mh-extra.com/html/sanken/ns-4a003-b/ns-4a003-b_instruction-manual_809248037.webp)
Function Code List-Input/Output Functions F14xx
~
F16xx
-36-
Input/Output Functions
F14xx
~
F16xx
Code
Function Name
Data Content
Setting
resolution
Factory
preset
1401
Bias frequency
(
VRF
)
0
~
±600
[Hz]
(
Frequency at 0V
)
0.1
[Hz]
0
1402
Gain frequency
(
VRF
)
0
~
±600
[Hz]
(
frequency at 5V
/
10V
)
0.1
[Hz]
60
1403
Bias frequency
(
V/I
)
0
~
±600
[Hz]
(
Frequency at 0V
/
4mA
)
0.1
[Hz]
0
1404
Gain frequency
(
V/I
)
0
~
±600
[Hz]
(
frequency at5V
or
10V
or
20mA
)
0.1
[Hz]
60
1407
External analog input
Filter time
(
VRF
)
1
~
500
(
set value
1=10ms
)
1
10
1408
External analog input
Filter time
(
V/I
)
1
~
500
(
set value
1=10ms
)
1
10
1410
Set frequency gain
0
~
100
1
0
1411
Analog input switching
For set frequency gain
0: No analog input
1: External analog VRF voltage
(
0
~
5V
)
2: External analog VRF voltage
(
0
~
10V
or potentiometer
)
3: External analog V/I voltage
(
0
~
5V
)
4: External analog V/I voltage
(
0
~
10V
or potentiometer
)
8: External analog V/I current
(
4
~
20mA
)
1
0
1412
MBS terminal input
Method
1
:
Level triggered
2
:
Edge triggered
1
1
1413
ES input signal
Functions
1
:
Normally open
2
:
Normally close
1
1