![Sanken NS-4A003-B Instruction Manual Download Page 30](http://html1.mh-extra.com/html/sanken/ns-4a003-b/ns-4a003-b_instruction-manual_809248030.webp)
Basic Operation Function F10xx
~
F13xx
Function Code List
-29-
Runing Function
F10xx
~
F13xx
Code
Function Name
Data Content
Setting
resolution
Factory
preset
1001
Motor control mode
selection
1
:
V
∕
f
Control Mode
2
:
Speed Control(Speed sensorless vector control)
3
:
Speed Control(Speedy sensor vector control)
10
:
Auto tuning mode 1
11
:
Auto tuning mode 2
40
:
V•f
separation control
1
1
1002
1st Speed frequency
Setting selection
1
:
Operation Panel
2
:
External analog
VRF
voltage
(
0
~
5V
)
3
:
External analog VRF
voltage(0
~
10V
or potentiometer)
4
:
External analog
V/I
Voltage
(
0
~
5V
)
5
:
External analog
V/I
voltage(0
~
10V
or potentiometer)
9
:
External analog
V/I
current
(
4
~
20mA
)
11: External analog
VRF
V/I
voltage
14: External analog
VRF
voltage-V/I
voltage
15: External analog
V/I
voltage-VRF
voltage
18: External analog
VRF
V/I
current
19: External
analog
VRF
voltage-V/I
current
20: External analog V/I
current-VRF
voltage
21: Terminal block stepping
22: Communication
25: Pulse Train Input
26: External analog
VRF
forward/reverse run
operation
(
0
~
10V
、
5V reference
)
27: External analog
V/I
forward/reverse run
operation
(
0
~
10V
、
5V reference
)
1
1
1003
V
∕
f
patten selection
1
:
Linear patten
2
:
Square-law decreasing patten (weak)
3
:
Square-law decreasing patten (strong)
1
1
1004
Torque boost
0
~
20%
(
Maximum voltage ratio
)
0.1%
※
1
1005
Base Voltage
400V
series
0
:
No
AVR
50
~
460V
1V
※
1
1006
Base Frequency
0.1
~
600Hz
0.01Hz
※
1