9-INSTALLATION INSTRUCTIONS
Boiler packaging content; boiler support styrofoam,
assembly hanger equipment, user manual,
warranty certificate and service booklet.
The places where the device will be mounted
should be selected by checking the conditions
determined by TSE and authorized gas
organizations. Mounting hanging equipment must
be securely mounted on the wall to carry the
weight of the boiler. The device must be mounted
on the hanging equipment to be level.
It is recommended to leave a gap of 50 cm from the
top, 15 cm from the sides and 40 cm from the
bottom where the boiler will be mounted. For
water connections, a filter and a ball valve must be
installed at the inlets of the combi. (Figure 5) The
mains inlet should not be over the 8 bar pressure
limit. In cases with higher network pressure, a pressure reducer must be installed.
The suitability of the gas installation and the device should be checked.
Warning: The safety valve connection must be
given to the installation drainage line.
Şekil 5
Safety
valve
Radiator out
going
connection
Domestic hot
water outler
connection
Gas
connection
Domestic hot
water inlet
Connection
Heater return
connecti on (inlet)
Figure 4