Note: The default standard pressure is set to 100 psi in factory.   

1.3 System Time Programming 

Function: The system clock was preset in the factory. It is the base of 

the alarm record, user can check the current date and time as 

follows: 

1.  When finish programming the standard pressure, press  P  to access 

interface  for  inquiry  and  programming  of  time/date,  the  first 

interface displays the year, 1 07 stands for the year 2007:   

                                           

 

2. Press ↓ key to access the second interface, 211 stands for November 

as shown below: 

                                           

 

Summary of Contents for TSB48-FR

Page 1: ...USER MANUAL TSB48 FR...

Page 2: ...transmitter has 4 groups of ID for example when program the transmitter with ID of 001 001 001 158 to front right tire position the user only needs to input the last 3 digits 158 Receiver will record...

Page 3: ...st the value 6 When finish programming these 3 digits press S for 3 seconds to save with the screen flashes twice beep buzzes twice Then it will automatically switch to next tire position 7 Repeat the...

Page 4: ...djust the value to 1 4 Once finished programming the first number press to program the second digit which flashes and then press up or down arrow key to adjust the value to 0 5 Once finished programmi...

Page 5: ...s the base of the alarm record user can check the current date and time as follows 1 When finish programming the standard pressure press P to access interface for inquiry and programming of time date...

Page 6: ...any interface of system time inquiry press S for 3 seconds to start programming For example change the year to 09 under the year interface press S for 3 seconds the second digit flashes press up or do...

Page 7: ...switch to the pressure unit interface As shown below 2 Under any interface displaying temperature or pressure press S key for 3 seconds to start programming Take change the temperature unit as an exam...

Page 8: ...ss S key for 3 seconds to delete with the screen flashes twice and beep buzzes twice to confirm the deletion Then it automatically switches to next transmitter location Note After programming press P...

Page 9: ...all programmed transmitters are received by the Receiver and the pressure or temperature are in proper state the screen displays ON 1 Installation of Transmitter Note 1 If a sensor is not learned by m...

Page 10: ...fter the sensor be installed the sensor can immediately sense the pressure and temperature inside the tire and transmit the collected data to the monitor The monitor will display the data on the scree...

Page 11: ...10 Storage temperature range 40 125 Transmitter weight about 24 g...

Page 12: ...the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Page 13: ...pareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produirede brouillage 2 l utilisateur de l appareil doit accepter tout brouillage r...