Instructions for programming
BB01 Board functions
25
© SandenVendo
5.7.6 ST6 Motor Reset After Door Close
ST6 = 0 no reset after door close
ST6 = 1 if a motor is not in home position the VMC reset the motor after door close
5.7.7 ST7 Coin Changer Keypad Managing
ST7 = 0 Key pad changer inhibited
ST7 = 1 Key pad changer used allowed
5.7.8 ST8 Machine Type
ST8 = 0 Normal (0 to 9 columns)
ST8 = 1 Tetra pack allowed (10 motors with 9 selection the last selection activated
alternative motor 9 and 10 until one of this column is empty)
5.7.9 ST9 MIS Reset
ST9 = 0 Resettable counters NOT reset after MIS audit performed
ST9 = 1 Resettable counters reset after MIS audit performed
5.7.10 ST10 Location code (programmable via windex program)
5.7.11 ST11 Revaluation with Coins to Cashless
ST11 = 0 Revaluation with coins to cashless possible
ST11 = 1 Revaluation with coins inhibited
5.8 Coin Acceptor Parameter Setting
(only for Executive eprom)
If the correct password is entered and if the ENTER button is activated at the "
ACCP
"
prompt the VMC will enter the coin rejector configuration setting routine. The display will
show a "
P01
" message where the "
1
" indicates the line of the rejector. Using UP and
DOWN button will cycle through the available line. Activation of the ENTER button while a
line number is displayed will allow access to the current value of the line. You can change
the value using UP and DOWN button (if it doesn’t work you must set the step using the
"
PB
" submenu).
Activation of the ENTER button will save the displayed value.
Using the submenu "
P01
"-"
P06
" you can change the value of the 6 lines of the rejector.
Using the submenu "
PB
" you set the step that you use on the line setting submenu.
Using the submenu "
PD
" you set the decimal point position.
Activation of the HOME button while configuration is displayed, without doing an ENTER
before, will return the VMC to the "
ACCP
" display without saving the displayed value.
Activation of the HOME button returns the VMC to the normal door open state.
5.9 Return to normal mode door open state routine
If the ENTER button is activated at the
"RTN
" prompt the VMC will exit the service mode
and return to the normal door open state.