Instructions for programming
BB01 Board functions
15
© SandenVendo
4.1 Error routine
If the ENTER button is activated at the
"EROR"
prompt the VMC will enter in the error
routine. If no errors have occurred since the last error reset the display will show a
"NONE"
message. If an error has been detected since the last error reset the display will
show the first summary level error code that has occurred, such as
"COLJ",
which would
indicate a column jam error. Using the UP or DOWN buttons will cycle through the various
summary level error. On the appendix A (Map of internal menu) you find all the error that
the machine can generate.
Activation of the BACK button while summary level error code is displayed will return the
VMC to the
"EROR"
prompt.
Activation of the BACK button at
"EROR"
prompt returns the VMC to the normal mode
door open state.
A simple way to clear all the error on the VMC is to put key on the door switch and
press the programming button on the electronic board.
Errors listing are :
COLJ
Column jam
VEND
Vend Mechanism
DOOR
Door open
SELS
Selection Switch
CHAR
Changer
CHUT
Chute/Carrier Switch
STS
Space to sales programming
BUAL
Bill Validator
CRDR
Card reader
4.1.1 Column Jam Error Routine
If the ENTER button is activated at the
"COLJ"
prompt the VMC will display a
"CJXX"
message where XX indicates the columns that have been detected as being jammed.
Using the UP and DOWN buttons will cycle through all jammed columns. If the ENTER
button is pressed and held for two seconds during the display of any error code, that code
will be cleared.
After clearing, VMC will display the next existing column jam error, or
"NONE"
if no other
error.
Activation of HOME button will return the VMC to the code level at the
"EROR"
message.