Instructions for programming
BB01 Board functions
20
© SandenVendo
The following information describes the various machine configuration settings
5.5.1 C1 Single price / Multi price
This setting is used to enable the single price mode. In this mode, all
columns
prices are
set to the value that is entered into the selection 1 price filed in the service mode. At the
prompt, "
C1
", after the activation of the ENTER button if the value = 1 the VMC is in the
single price mode. If the value is set to 0 the multi-price mode is enabled (default).
5.5.2 C2 Low change equation
IN MDB
This parameter defines the exact change equation. The combination of the empty tube
states assume the exact change state. "CHANGE EQUATION" if empty tubes are:
0 : TUBE A and TUBE B and TUBE C and TUBE D
1 : TUBE A or TUBE B or TUBE C
2 : TUBE A only
3 : TUBE B only
4 : TUBE C only
5 : TUBE D only
6 : TUBE B or TUBE C or TUBE D
7 : TUBE A and TUBE B or TUBE C
8 : TUBE A and TUBE B or TUBE D
9 : TUBE A and TUBE C or TUBE D
10 : TUBE B and TUBE C or TUBE D
11 : TUBE A and TUBE D or TUBE C
12 : TUBE B and TUBE D or TUBE A
13 : TUBE C and TUBE D or TUBE D
14 : TUBE A or TUBE B and TUBE C
IN EXECUTIVE
C2= 0 Normal Executive mode. Vend prices managed by VMC (Vending Machine Control).
C2= 1 Price Holding Mode. Vend prices are set in coin changer. Coin Changer must be set
for Price Holding Mode.
5.5.3 C3 Low change level
IN MDB
This parameter is used to set the minimum number of coins for setting the changer in low
change.
IN EXECUTIVE
Offset send with the selection should be at 0
5.5.4 C4 Single / Multi vend
(only MDB)
This parameter is used to allow the multivend or not
1 single vend (give exchange after selection)
0 multivend (keep extra money for other selection)