4.6 Set up Auto Report
Use this command to set up the frequency of Auto Report. If you send the SMS according to the
example shown below to CT-58, you will have an Auto Report Message every 300 seconds for 99
messages. Once the loop is done, you can send a SMS message to update/renew, or switching off
it in order to renew it.
Note
: You may limit the amount of the Auto reply messages by inputting the digits from 1 to 9998
in the
「
total number of report
」
field. When you input 9999, the Auto Report Message will not stop
unless you define a new Auto Report Setting.
Setup format
#「
username
」
,
「
Password
」
,
「
Function Code
」
,
「
intervals (sec)
」
,
「
total number of report
」
,
「
distance
interval(m)
」
,
「
stationary detection(times)
」*
Example1
:#
username,0000,6,300,99,10,10
*
The table 4.6.1 describes the meaning of each segment in the message above.
Table 4.6.1
Text Keyed In SMS Description
#
Start sign.
username
Default ID of CT-58.
If you have changed the Username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
6
Mode 6 defines to change the intervals and times of sending-back data
300
A constant interval of sending data
99
The amount of 99 messages sent automatically
10
Distance Interval
: when the auto report function is activated, the
tracker will take the current position as the center point, if this value is
defined, the tracker will take this distance as the radius to make a circle.
When the tracker exceeds this circle, the alarm report will be sent to the
assigned router. The unit of this function is
meter
.
10
Stationary Detection
: If this value is defined by 5, the tracker will
detect if the tracker exceeds the circle for 5 times. If the tracker doesn’t
exceed this circle, the tracker will send a notice message. The unit is
times
.
*
End sign.