4-4. Communication (G.COM)
4-4-1 Protocol selection
▪ Select a Protocol to use.
▪ Select PCC0 for PC Link or select PCC1 for PC Link with sum check.
Symbol
Parameter
Setting range
Display
Unit
Default
COM.P
Communication
Protocol
PCC0, PCC1, MBS.A,
MBS.R, SYN.M, SYN,S
/RS Option
ABS
PCC1
4-4-2 Baud rate
▪ Set the baud rate, communication speed.
Symbol
Parameter
Setting range
Display
Unit
Default
BAUD
Baud Rate
4800, 9600, 19.2K, 38.4K
/RS Option
ABS
9600
4-4-3 Parity
▪ Set the parity.
Symbol
Parameter
Setting range
Display
Unit
Default
PRTY
Parity
NONE, EVEN, ODD
/RS Option
ABS
NONE
4-4-4 Stop Bit
▪ Set the stop bit.
Symbol
Parameter
Setting range
Display
Unit
Default
S.BIT
Stop Bit
1, 2
/RS Option
ABS
1
4-4-5 Data Length
▪ Set the data length.
Symbol
Parameter
Setting range
Display
Unit
Default
D.LEN
Data Length
7, 8
/RS option
COM.P = PCC0, PCC1,
SYN.M, SYN.S
ABS
8