Note) INA terminal
•When use as a counter :
“
count input
”
or
“
count stop input
”
signal input terminal
•When use as a timer : “START”signal input terminal.
Note) INB/INH terminal
• When use with counter : INB become signal input terminal.
• When use with timer : INH(Inhibit) become signal input terminal.
If signal of the INH terminal active the timer become stop timer
.(Time Hold)
6. INPUT TERMINAL WIREING DIAGRAM
1) INPUT: NON VOLTAGE INPUT(NPN)
(1) NO ELECTRIC CONTACT INPUT
(2) ELECTRIC CONTACT INPUT(SET THE COUNTER COUNT TIME SPEED BETWEEN 1 AND 30cps.)
③
※
+12V
SIGNAL INPU
COUNTER/TIMER
0V
5.6K
Ω
※ INA(
①
), INB(
②
), RESET(
⑤
),
INHIBIT(
⑥
), BATCH RESET(
⑦
),
INPUT PART
INA(
⑤
), INB/INH(④),
RESET(
①
) INPUT
SENSOR
SENSOR
COUNTER/TIM
ER
COUNTER/TIM
ER
5.6K
Ω
5.6K
Ω
③
④
②
※
+12V
SIGNAL
INPUT
(NPN VOLAGE OUTPUT
)
③
④
※
(NPN OPEN COLLECTOR OUTPUT
)
0V
0V
④
④