![Samsung SNT-1010 User Manual Download Page 42](http://html.mh-extra.com/html/samsung/snt-1010/snt-1010_user-manual_354493042.webp)
83
Specifications
Chapter 9 Appendix
Trouble-shooting/Specifications
Appendix
Trouble-shooting
(Continued)
Appendix
82
I can’t control over the PTZ device
First, check the settings of <SETUP>
<SYSTEM>
<RS485>.
Refer to the user guide of the external device connected to SNT-1010 for correct settings.
The menu of the external PTZ device appears somewhat later.
Or, the response from the external PTZ is delayed when I manipulate it.
The amount of data is comparatively great considering the network transfer rate.
In <SETUP>
<BASIC CONFIGURATION>
<VIDEO> set the <Resolution> to <CIF> or, the <Low>.
When my SNT-1010 has restarted, the [Status] indicator still stays red.
First, check the settings of <SETUP>
<SYSTEM>
<DATE/TIME>.
This is due to a connection failure to the NTP server. So It couldn’t display the time information.
I have selected Set in the IP Installer list and pressed the [Manual Set] button. But I couldn’t
change the IP address and port number.
Check the [IP Type ] switch on the front panel for the position.
If the switch is positioned to [D], this is in Dynamic IP mode.
In this case, the IP address and port number are allocated by DHCP, which you can’t change.
For [Auto Set], why the IP address and port number are changed when the port
mapping has failed?
[Auto Set ] will perform both the IP and Port setting and [Port Mapping ].
You can change the IP address and port number, regardless of the [Port Mapping] results.
The port mapping for both [Auto Set] and [Manual Set] does not work.
Check the current IP sharer for compatibility with SNT-1010.(see page 5)
If your IP sharer is listed in the list, check if the UPnP check box is selected on the main
menu window of the sharer (normally, 192.168.1.1).
If not listed, check your IP sharer for UPnP accessibility and if the problem persists, replace it with one in the list.
When I connect SNT-1010 to the power source, the status indicator keeps blinking in red and I
can’t connect to the network using the browser.
If SNT--1010 fails to connect to the set NTP server,it attempts to connect to other NTP servers.So if
the IP settings of the SNT-1010 are incorrectly configured or the network environments are not in
normal conditions,it will take as long as several minutes to restart the SNT-1010.
You can access the network when the status indicator turns into red or green.
OS
Browser
DirectX
CPU Hardware
Network
Video
Audio
Compression
Video resolution
Frame Rate
Video Quality
Motion Detection
Alarm I/O
Alarm Event
SNT-1010
PC
Physical layer
Network Protocol
Streaming
UPnP
DDNS
IN
OUT
connector
Input/Output
Bidirectional audio
Video
Audio
NTSC
PAL
NTSC
PAL
10/100BASE-T
TCP, UDP, NTP, HTTP, DHCP,
TCP, UDP(Unicast, Multicast)
Supporting Auto Network Configuration
Supporting Samsung DDNS and Public DDNS servers
Composite 1 Channel
1 BNC (Loop Through Out)
- Auto Termination
3.5 mm jacks
Mono 1 chanel / Mono 1 channel,
Full duplex Supporting
MPEG-4, M-JPEG
G.711, 64kbps 8kHz sampling
D1
VGA
CIF
QCIF
D1
VGA
CIF
QCIF
720x480
640x480
352x240
176x112
720x576
640x576
352x288
176x144
30, 15, 7.5, 3, 1 FPS
25, 12.5, 6.25, 3, 1 FPS
Quality
Sensitivity
Alarm Input
Video Loss
Motion Detection
Schedule
Very High, High, Normal, Low, Very Low
High, Medium, Low
Image transfer : FTP, E-mail
Notification :notify to viewer and file server Alarm Out
Image transfer : FTP, E-mail
Notification :notify to viewer and file server Alarm Out
Image transfer : FTP, E-mail
Notification :notify to viewer and file server Alarm Out
Image transfer : FTP, E-mail
Input :4 Input (5 mA sink)
Output 1 (24VDC 40mA Max)
Relay OUT (30VDC 2A,125VAC 0.5A Max)
Internet Explorer 5.0 or Higher
DirectX 8.1 or Higher
32bit RSIC
Flash 16Mbyte
SDRAM 32Mbyte
Embedded Linux
Windows XP / Windows 2000 Professional