PANEL TRASERO
A.CAMERA INPUT / LOOP THROUGH OUT
- Up to 16 camera signals can be input. When transmitting camera signals to external devices, OUT
terminal can be used.
B.ALARM IN / ALARM OUT / VTI TERMINAL
- VTI: TRIGGER Output Connection terminal of VCR
- ALARM IN: Up to 16 ALARM Sensors can be connected. “G” indicates grounding terminal connected
to ALARM Input, and should be connected to grounding terminal of sensors.
- ALARM OUT (HOT/COLD): When ALARM is activated, ACTIVE MAKE Signal is generated.
- ALARM RESET : Connected to RESET terminal of VCR, and when ALARM is deactivated, PULSE is
generated.
C.VCR IN/OUT (BNC)
Indicates terminal for connecting to VCR Input/Output.
D.MONITOR OUT (BNC)
Indicates terminal for connecting to Monitor’s video Input terminal.
E.SPOT OUT (BNC)
Indicates terminal for connecting to Monitor’s video Input terminal.
F. VCR IN/OUT (4PIN MINI DIN)
Indicates terminal for connecting to VCR’s S-VHS Input/Output terminal.
✴
SDM-160M/SDM-160MP:Not used.
G. MONITOR OUT (4PIN MINI DIN)
Indicates terminal for connecting to Monitor’s video S-VHS Input terminal.
✴
SDM-160M/SDM-160MP:Not used.
H.RS-232C
With RS-232C cable, Remote Control can be done.
I. RS-485
With RS-485 cable, Remote Control can be done.
J. ~AC IN
Connects to Power Cord.
Digital Multiplexer
1-4
ENGLISH
F
I
B
E
D
G
H
A
C
J
-AC IN
SDM160 12/10/01 11:06 AM Page 1-4