English_15
●
CONNECTION
Connector
Function
Signal Level
I/O
ZOOM
Tele
+6V ~ +12V
COM
I
Wide
-6V ~ -12V
COM
FOCUS
Far
+6V ~ +12V
COM
I
Near
-6V ~ -12V
COM
COM
COM
-
ALARM OUT
USER Vcc (3V~5V)
0V
5±0.5sec
←
→
O
EX DN
DAY mode : D&N terminals must be OPEN to external signals.
(Do not input voltage)
NIGHT mode : D&N terminal must be connected to the ground
I
Do not simultaneously connect the RS-485 (+) (-) communication line when you
use voltage control ZOOM and FOCUS, using the RECEIVER BOX (SRX-100B).
ALARM Output format is open collector.
* Match the communication setup between devices when you use the wired
controller (SPC-200) or SPC-6000.
I
ITEM
SPC-200
SPC-6000(Factory Default)
MODE
Serial
Serial
Data Bit
8 bit
8 bit
Bit/Sec
9600bps
9600bps
Parity
EVEN
NONE
CAM ID NO.
0
1~255
RETURN PACKET
ENABLE
See the SPC-6000 manual