ELECTRICAL DATA
3C80A5B
13-
6
Table 13-8. Oscillation Stabilization Time
(T
A
= – 25
°
C + 85
°
C, V
DD
= 5.5 V)
Oscillator
Test Condition
Min
Typ
Max
Unit
Main crystal
f
OSC
> 400 kHz
–
–
20
ms
Main ceramic
Oscillation stabilization occurs when V
DD
is equal
to the minimum oscillator voltage range.
–
–
10
ms
External clock
(main system)
X
IN
input High and Low width (t
XH
, t
XL
)
25
–
500
ns
Oscillator
stabilization
wait time
t
WAIT
when released by a reset
(1)
–
2
16
/
f
OSC
–
ms
t
WAIT
when released by an interrupt
(2)
–
–
–
ms
NOTES
:
1. f
OSC
is the oscillator frequency.
2. The duration of the oscillation stabilization time (t
WAIT
) when it is released by an interrupt is determined by the setting
in the basic timer control register, BTCON.
1.33 MHz
250 kHz
8.32 kHz
1
2
3
4
5
6
7
Supply Voltage (V)
Instruction Clock = 1/6n x oscillator frequency (n = 1, 2, 8, 16)
1.00 MHz
500 kHz
670 kHz
Instruction
Clock
8 MHz
6 MHz
4 MHz
Instruction
Clock
400 kHz
Figure 13-2. Operating Voltage Range of S3C80A5B