Electrical Connections
Connection of the power cable (1 phase 2 wires)
Circuit
breaker
Distribution board
Outdoor unit
Indoor unit
1 phase
2 wires
220-
240V~
Earth
Communication cable
220V
Wired remote
controller
Earth
Connection of the power cable (1 phase 2 wires using EEV kit)
Distribution board
Outdoor unit
Indoor unit
Circuit
breaker
1 phase
2 wires
220-
240V~
Earth
Communication cable
Wired remote
controller
EEV kit
Circuit
breaker
Circuit
breaker