Defrost Control From 6 to 13 hrs(Only 230V, 50Hz)
Defrost Contro From 6 to 11 hrs(All Model)
Defrost Thermistor(502AT) 59
℉
/15°C(off)
Electrical Rating Refer to the label on Refrigerator
Maximum Current Leakage 0.25 mA
Maximum Ground Path Resistance 0.1Ohm
Energy Consumption
Refer to the label on Refrigerator
Bimetal 104
℉(on)/
140
℉
(off)
Ambient Temperature 70
℉/21.1
°C
90
℉/21.1
°C
Refrigerator,
℉/
℃
3 4
∼
4 6
℉/1.1~7.8
°C 3 4
∼
4 6
℉/1.1~7.8
°C
Freezer,
℉
-11
∼
7
℉/23.9~-13.9
°C -11
∼
7
℉/23.9~-13.9
°C
Run Time,% 40 60
Refrigerant Charge (R134a)
6.17 oz(Only for America)
Compressor(MK183C-L2U)
1032 Btu/hr(Only for America)
Compressor oil Freol
α
-15
Capillary tube(Dia, Length) 0.033
"
"
,130
"
"
Dryer Molecular Sieve XH-9
Clearance must be provided for air circulation
AT TOP (1
"
"//22..55ccm
m))
AT SIDES (1/8
"
"//00..33ccm
m))
AT REAR
(1
"
"//22..55ccm
m))
RS2530B**
PBA MAIN
················
DA41-00219K
PBA PANEL
···············
DA41-00406A
TRANS DC(115V/60Hz)
·······
DA26-00022A
SENSOR(DEF SENSOR)
······
DA32-00006D
SENSOR(F SENSOR)
········
DA32-00006D
SENSOR(R SENSOR)
········
DA32-00006B
SENSOR(ICE MAKER SENSOR)
·
DA32-10108B
RELAY
··················
DA35-10013Q
OVERLOAD REALY
·········
DA34-10003S
RUN CAPACITOR(12 MF)
······
2501-001045
FAN MOTOR(FREEZER)
······
DA31-00003W
FAN MOTOR(UNIT)
··········
DA31-00103A
15. Specifications
Compressor
Dryer
Electric box
Sub-Condenser
ELECTRICAL SPECIFICATIONS
Freezer
Refrigerator
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
98
MODELS
REPLACEMENT PARTS
Summary of Contents for RS2530BSH
Page 10: ...10 2 3 Model Specification Comparison Chart PRODUCT SPECIFICATIONS ...
Page 76: ...8 BLOCK DIAGRAM 8 1 BLOCK DIAGRAM 76 ...
Page 77: ...BLOCK DIAGRAM 8 2 CONNECTOR ARRANGEMENT AND DETAIL EXPLANATION 77 ...
Page 79: ...PCB DIAGRAM 9 2 SUB PCB CONNECTOR CONFIGURATION 79 ...