30
ALIGNMENT AND ADJUSTMENTS
NO
Item
DISPLAY LED
Description
How to Self-Diagnose
Refrigerator
SENSOR
1
Refrigerator "MID"
Fall out SENSOR HOUSING in
Refrigerator contanct failture, breakage of
wire, short-circuit, inferior Refrigerator
SENSOR and others.
Indicating a defect when the temp sensing
of Refrigerator SENOSR is above
(149°F/65 °C) and below (-58 °F/-50 °C).
The voltage should be within the range of
4.7V~0.6V between MAIN PCB CN30 #
8 and #9.
Peripheral temp
SENSOR
2
Refrigerator "MIN"
Fall out peripheral temp SENSOR
HOUSING , contact failure, breakage of
wire, short-circuit, inferior peripheral
sensor and others.
Indicating a defect when the temp sensing
of peripheral temp SENOSR is above
(149°F/65 °C) and below (-58 °F/-50 °C).
The voltage should be within the range of
4.7V~0.6V between MAIN PCB CN31 #
1 and #4.
Freezer SENSOR
3
Freezer "MAX"
Fall out SENSOR HOUSING in Freezer,
contact failure, breakage of wire, short-
circuit, inferior Freezer SENSOR and
others.
Indicating a defect when the temp sensing
of Freezer SENOSR is above
(149°F/65°C) and below (-58 °F/-50 °C).
The voltage should be within the range of
4.7V~0.6V between MAIN PCB CN30 #
4 and #5.
Freezer Defrost
SENSOR
4
Freezer "MID"
Fall out Deforst - SENSOR HOUSING in
the evaporator of Freezer, contact facilure,
breakge of wire, short-circuit, inferior
sensor and others.Indicating a defect when
the temp sensing of Freezer Defrost
SENOSR is above (149 °F/65 °C) and
below (-58 °F/-50 °C).
The voltage should be within the range of
4.7V~0.6V between MAIN PCB CN30 #
4 and #6.
Freezer Defrost
ERROR
5
Freezer "MIN"
Fall out Freezer Heater Housing, contact
failture, breakage of wire, short circuit,
inferior Freezer Heater, or inferior Defrost
temp fuse and etc.
On Freezer Defrost 90 min. automatic
completion
I/M Function
ERROR
6
ICE OFF
Ejection restoration failure more than 3
times.
Push the test buttono nI/
MAss'y and It should work.
I/M SENSOR
ERROR
7
Cubed LED
Fall out I/M SENSOR HOUSING, contact
failure,brekage of wire,short-circuit, inferior
I/M-SENSOR and etc.
The voltage should be within the range of
4.7V~0.6V between MAIN PCB CN90 #
3 and #4.
DAMPER HEATER
8
Refrigerator "MAX"
Damper Heater Slipped Away, Poor
Contact, Wire Breakage, Short Circuit,
Defective Damper Heater
Indicates error when the Damper Heater is
detected as open (Only for Energy Star)
F-FAN RESTRAINT
9
Crushed Ice
F-Fan Restraintor Defect
Upon detection of F-Fan restraint
(Only for Energy Star)
C-FAN RESTRAINT
10
Crushed Ice
(Blinking)
C-Fan Restraintor Defect
Upon detection of C-Fan restraint
(Only for Energy Star)
Details of self-diagnosis lighting by
Summary of Contents for RS2530BSH
Page 10: ...10 2 3 Model Specification Comparison Chart PRODUCT SPECIFICATIONS ...
Page 76: ...8 BLOCK DIAGRAM 8 1 BLOCK DIAGRAM 76 ...
Page 77: ...BLOCK DIAGRAM 8 2 CONNECTOR ARRANGEMENT AND DETAIL EXPLANATION 77 ...
Page 79: ...PCB DIAGRAM 9 2 SUB PCB CONNECTOR CONFIGURATION 79 ...
Page 80: ...80 10 WIRING DIAGRAM ...
Page 81: ...11 CIRCUIT DIAGRAM 81 ...