95
TROUBLESHOOTING
4-2-9. When Compressor does not run (Inverter COMP.)
Refer to the TEST
Function in this manual
Start
Check in 10 minutes
Replace MAIN PBA or
Repair the connection
Replace F-Sensor
10 minutes have
passed since COMP
was off
No
No
No
1) Check the COMP Wire
2) Check the Compressor
Make sure the connector is
plugged properly.
Replace COMP ASS'Y
No
No
1) Check the wire harness
2) Replace the MAIN PBA
0~800Hz 50% Duty
Signal Output
No
Check the Noise Filter &
Power Cord
Make sure the connector is
plugged properly.
No
No
Repair the sensing
part or Replace
MAIN PBA
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
When Forced Operation
mode is activated, COMP
operates
COMP operation signal
(CN103 #1 <>#3) is about
DC2~3V
Is DC 15V applied to
ZD501?
AC input applied to
CN101?
COMP Connector (CN102) is
Good?
Is DC 5V applied to
C108(C110)?
No
COMP ASS'Y is Good
F-Sensor is Good
Temperature sensing
part of MAIN PBA is
Good
Normal
Forced Operation signal sound
should be checked