TROUBLESHOOTING
8) If Ice Room Sensor has trouble
ERROR Code
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN78 and CN76 inserted
correctly?
Is Ice room sensor unit normal?
Is the voltage between
MAIN PCB Connector CN78-"10"(Orange) and
REG1-GND normal?
Is the input voltage of
IC01 MICOM #11 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the wiring connection
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder
bridging, disturbed solder
NO
No trouble with PCB and temperature sensor.
Check the bad connections.
** Measuring point of resistance value according to
Sensor **
Ambient : CN78 ”10”
↔
CN76-”1” Measure the voltage
of Resistance value
** 0
Ω
: Short trouble /
Ω∞
: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #11,
CN78-"10"(Orange) and REG1-GND from
PCB Typical Ground are similar.
→
Check the measure on the voltage of Resistance,
R316 due to the SMD MICOM
☞
Checking Mehod of Ice Room Sensor voltage
CN78-"10"(Orange)
↔
CN76-”1” (Gray)
- Compare with the temperature table after
measurement.
DATA1.
Temperature table
Refer to the circuit diagram in this manual
Ice Room Connector CN78-"10"(Orange) and
REG1-GND from PCB Typical Ground
☞
Checking Method of Ice Room Sensor Voltage
- Measure the voltage of Resistance, R316(IC01 MICOM #11) on PCB or
CN78-"10"(Orange)
↔
REG1-GND
- Compare with the temperature table after measurement.
Measured voltage of CN78-"10"(Orange)
↔
REG1-GND are as below
PCB Typical Ground
REG1-GND
Start
YES
YES
YES