93
TROUBLESHOOTING
4-2-7. If FDSR Door Heater does not operate
Start
**Measuring point of resistance value according to heater**
FDSR Door Heater :
CN73_1 “13”(Red) <->CN72”3”(Gray) Measuring
Resistance value(63 ohm ± 7%)
**0Ω : Short trouble / Ω∞ : Open(bimetal, heater) trouble
Are the FDSR Door
heater normal?
No
Yes
Check soldering
short/Replace PCB
Check the heater disconnection,
wiring connection etc.
Does Main PCB IC01
MICOM #90 voltage change
5V/0V?
No
Yes
Check soldering
short/Replace PCB
Does Main PCB
IC73-”7” have about 0.7V
Input?
No
Yes
Check soldering
short/Replace PCB
Check soldering
short/Replace PCB
Does Main PCB
IC73-”10” have about 0.7V
output?
Is the contact
point of main PCB RELAY RY78
normal?
No
No
Yes
Yes
MAIN PCB normal
-- Need to check the other parts
①
Check the wire between Ice
water valve
↔
MAIN PCB
②
Ice water valve itself has
trouble or bad contact of
connector
③
Check the connection hose
1. Please shut the water supplying prior to repair.
2. Power is applied to the one end of wires. Be careful when disassembling not to get an electric shock.
PCB Typical Ground REG1-GND
☞
Checking method of voltage Based on PCB
typical Ground REG1-GND
1) Check the voltage of IC73-”7”
- ICE Water valve waiting (about 0V)
Based on PCB typical Ground REG1-GND
2) IC73-”10” voltage
- ICE Water valve Waiting (about 12V
±
0.8V)
- ICE Water valve operating (about 0.7V
±
0.5V)
3) Check the voltage of Water Valve operating
(AC voltage)
=> For checking the Relay SSR76 operating.
CN73_1 “13”(Red) <->CN72”3”(Gray)
- FDSR Door Heater Operating at (about AC
110V)
1) Ice Water(R) Valve