66
TROUBLESHOOTING
※
Load mode Check list
Display LED
Display contents
Operation contents
R-1-ⓐ
R-FAN High
When FF compartment FAN operates with high speed, applicable
LED ON
R-1-ⓑ
R-FAN Low
When FF compartment FAN operates with low speed, applicable
LED ON
R-1-ⓒ
R-DEF Heater
When FF compartment defrost heater operates, LED ON
R-1-ⓓ
Showcase Door Heater
When Showcase Door heater operates, applicable LED ON
R-1-ⓔ
Overload condition
When ambient temperature is more than 93℉(34°C), LED ON
R-1-ⓕ
Low temperature condition When ambient temperature is less than 72℉(22°C), LED ON
R-1-ⓔ,ⓕ
(ALL LED Off)
Normal Condition
When ambient temperature is between 73℉(23°C) and 91℉(33°C)
R-1-ⓖ
Exhibition Mode
LED ON at the display mode.
F-1-ⓐ
COMP.
When COMP operates, applicable LED ON.
F-1-ⓑ
F-FAN High
When FZ compartment FAN operates with high speed, applicable
LED ON.
F-1-ⓒ
F-FAN Low
When FZ compartment FAN operates with low speed, applicable
LED ON.
F-1-ⓓ
F-DEF Heater
When FZ compartment defrost heater operates, LED ON
F-1-ⓔ
C-FAN High
When compressor FAN operates with high speed, applicable LED
ON.
F-1-ⓕ
C-FAN Low
When compressor FAN operates with low speed, applicable LED
ON.
R-10-ⓐ
Pantry Room Damper Open When damper open, applicable LED ON
R-10-ⓓ
Ice maker full(FF)
When the Ice Maker's Bucket is full, applicable LED ON in FF-room
R-10-ⓔ
Ice maker full(FZ)
When the Ice Maker's Bucket is full, applicable LED ON in FZ-room
R-10-ⓕ
More Heater (F Pipe water
heater)
Add to Assy Water Pipe Heater in FZ-room
F-10-ⓓ
Ice Room-FAN High
When Ice Room-FAN operates with high speed, applicable LED
ON.
F-10-ⓔ
Ice Room-FAN Low
When Ice Room-FAN operates with low speed, applicable LED
ON.
F-10-ⓖ
French Heater
When French heater operates, applicable LED ON